MODEL OM 500 SPECIFICATIONS
Input Volts: 120 VAC, 60Hz, Single Phase
208-230/460 VAC, 3-Phase (Optional)
Max. Current:
120 VAC
10.4 Amps
208-230 VAC
3.2 Amps
460 VAC
1.6 Amps
Motor:
3/4 HP TEAO
1 HP TEAO 3-Phase (Optional)
Air Flow*:
6” Inlet
665 CFM (3387 FPM)
8” Inlet
800 CFM (2292 FPM)
Dimensions:
49” H x 26” W x 14” D (without wall brackets)
Shipping Weight:
175 lbs.
Actual Weight:
155 lbs.
* All air flows are tunnel tested readings.
PACKAGE CONTENTS
1 ea.
OM 500 Unit
2 ea.
Wall Mount Brackets
1 ea.
Owner’s Manual
PRE-OPERATING INSTRUCTIONS
1.
Cut banding material and remove cardboard and plastic from unit. Remove unit
from shipping skid.
2.
Inspect unit for shipping damage and report any damage to freight carrier.
INSTALLATION INSTRUCTIONS
A. WALL MOUNT
1. Remove four 5/16” bolts from sides of cabinet near top and bottom of unit.
2. Use bolts removed in Step 1 to secure wall mount brackets to unit
as shown in
FIG. 1
.
3.
Locate an installation site that will provide for the following:
•
A solid structure, capable of supporting the weight of the unit.
•
Three feet of unobstructed exhaust space from the outlet of the unit.
•
Easy access to service panels and unit inlet.
•
As near as possible to the source of oil mist unit to be captured.
FIG. 1
FIG. 2
4.
Mark location of mounting holes on the surface to which unit is to be mounted
(see
Figure 2
for hole pattern). Drill holes that are sized correctly for the
hole pattern in mounting hardware.
5.
Position the OM 500 wall mount bracket holes over the holes located on the
structure in Step 4. Use 3/8” x 2” lag bolts or 3/8” bolts and nuts to secure
the OM 500 to structure.
CAUTION: The size and weight of the OM 500 requires two persons or
mechanical means to lift and hold during mounting.
6.
Connect unit to oil mist source using a duct having the same diameter as
the inlet of the unit. The duct may be flexible hose or formed sheet metal.
Maximum flow will be obtained with minimum bends in duct. To contain oil
that will collect on the inside of the duct, the duct must be sealed. Sloping
the duct toward the OM 500 will assist flow. Use hose clamps or sheet
metal screws to attach duct to unit.
NOTE:
Optional hose adapters are available for connection to 6” and 8”
diameter hose. Use Part No. 34145-01 for 6” diameter hose, and Part No.
34145-02 for 8” diameter hose. Attach adapter to plenum collar with sheet
metal screws and seal with RTV sealant.
B.
FLOOR MOUNT
NOTE:
The optional base assembly (Part No. 38162-01) is required for floor
mount installation.
1.
Locate an installation site on a level surface that will meet the requirements
listed in Step 3 of the wall mounting instructions.
2.
Set the base in place and lift the unit onto the base.
CAUTION: The size and weight of the OM 500 requires two persons
or mechanical means to lift and hold during mounting.
NOTE:
You may want to bolt the base to the floor.
3.
Connect the unit to the oil mist source as explained in Step 6 of the wall
mounting instructions.
C.
CEILING MOUNTING
NOTE:
The optional ceiling mounting kit (Part No. 38088-02) is required for ceiling
mount installation.
1.
Remove the two (2) 5/16” bolts from the side of the cabinet at
2.
Use the bolts removed in Step 1 to secure the ceiling mount brackets to the
unit as shown in
FIG. 3
.
2
OM500