background image

OM 500 - PARTS LIST

FIG. 7

ITEM

PART NO.

DESCRIPTION

ITEM

PART NO.

DESCRIPTION

1.

34126-01

Cabinet Weldment

15.

P1954

Strain Relief (not shown)

2.

34142-03

Inlet Plenum (3”-8” collars)

16.

34150-01 Control Box Cover

3.

34094-02

Wall Bracket (2 ea. required)

17.

P1372

Door Latch (2 ea. required)

4.

34122-01

Blower/Rivnut Assembly (120 V & 220 V)

18.

34136-01 Filter Access Door

5.

34148-01

Exhaust Panel

19.

P2126

Gasket (specify length required)

6.

P1717

Motor (120 V)

20.

34161-01 Optional Hepa Kit

P1762

Motor (208-230/460 V)

21.

P2250

Optional Magnehelic Gauge

7.

P2064

Belt

          Not Shown

P2061

Oil Impinger

8.

P1789

Motor Pulley

          Not Shown

P2062

Oil Bag Filter

 9.

P1710

Blower Pulley

          Not Shown

P2072

Optional Hepa Filter

10.

34134-01

Front Access Panel

          Not Shown

P2070

Optional Oil Bag Filter

11.

P1429

Lamp (120 V)

 (used with Hepa Filter)

P1481

Lamp (220 V)

          Not Shown

P3001

Optional 2” Max Grid Panel Filter

12.

P1428

Pressure Switch

                          Not Shown

P3008

Optional 4”Mist-Xfilter (Chevron)

13.

P1356

ON/OFF Switch

          Not Shown

34088-02 Optional Ceiling Bracket (2 ea. required)

14.

P1363

Power Cord

          Not Shown

34162-01 Optional Base Assembly

          Not Shown

34145-01 Optional 6” Diameter Collar Adapter

7

OM500

Summary of Contents for OM 500

Page 1: ...Model OM 500 OWNER S MANUAL CAUTION Read complete instructions before operating Please file for future reference AIR CLEANERS ...

Page 2: ... 4 Use 3 8 x 2 lag bolts or 3 8 bolts and nuts to secure the OM 500 to structure CAUTION The size and weight of the OM 500 requires two persons or mechanical means to lift and hold during mounting 6 Connect unit to oil mist source using a duct having the same diameter as the inlet of the unit The duct may be flexible hose or formed sheet metal Maximum flow will be obtained with minimum bends in du...

Page 3: ...ly circuit to this unit See Wiring Diagram FIG 6 2 Remove the front motor compartment access cover 3 Remove the electrical wiring box cover 4 Make electrical connections to the input wires as shown in Wiring Diagram FIG 6 for three phase wire connections NOTE The filter change indicator light circuit must be supplied with no more than 270V If a 460V 3 wire source is used a transformer replacement ...

Page 4: ...t pre lube design Excessive dirt oil should be periodically removed 4 Make sure oil is draining easily through drain pipe FIG 5 CHANGING FILTERS CAUTION Always make sure that the unit is turned off before changing filters or servicing the unit 1 The OM 500 is equipped with a filter change light or an optional Magnehelic Gauge which indicates when a filter needs to be replaced If the differential p...

Page 5: ...wire Burned out motor Replace motor Unit runs slowly or Wired for wrong voltage or Check input voltage Inadequate capture velocity Improper rotation Check wiring diagram Dirty filters Service filters see Changing Filters section Obstruction in hose arm Reach into hood and assembly remove obstruction Pulleys set for static Adjust or change pulleys Vibration Loose mounting bolts Tighten bolts Foreig...

Page 6: ...OM 500 WIRING DIAGRAM 6 OM500 FIG 6 ...

Page 7: ...762 Motor 208 230 460 V 21 P2250 Optional Magnehelic Gauge 7 P2064 Belt Not Shown P2061 Oil Impinger 8 P1789 Motor Pulley Not Shown P2062 Oil Bag Filter 9 P1710 Blower Pulley Not Shown P2072 Optional Hepa Filter 10 34134 01 Front Access Panel Not Shown P2070 Optional Oil Bag Filter 11 P1429 Lamp 120 V used with Hepa Filter P1481 Lamp 220 V Not Shown P3001 Optional 2 Max Grid Panel Filter 12 P1428 ...

Page 8: ...NOTES AIR CLEANERS Products of Metal Fab Inc P O BOX 1138 WICHITA KS 67201 1998 Metal Fab Inc Form No L1142 11 02 7051 Litho in U S A 8 OM500 ...