Page 28
Assembly
optoNCDT 1900 / EtherCAT
5.2
Mechanical Fastening, Dimensional Drawing
5.2.1
General
The optoNCDT 1900-IE sensor is an optical system used to measure in the millimeter range. If the laser beam does not strike the
object surface at a perpendicular angle, measurements might be inaccurate.
i
Ensure careful handling of the sensor during installation and operation. Mount the sensor only
to the existing through-bores on a flat surface. Any type of clamping is not permitted. Do not
exceed torques.
The bearing surfaces surrounding the through-holes (fastening holes) are slightly raised.
Fig. 12 Sensor mounting with diffuse reflection
5.2.2
Mounting
Depending on the installation position, it is recommended to define the sensor position using centering elements and fitting bores.
The cylindrical counterbore ø6 H7 is intended for the position-defining centering elements. This allows for the sensor to be mounted in
a reproducible and exchangeable way.
Bolt connection
Direct fastening
0.75 Nm
2.0 Nm
min 10
(.04)
M3 x 40; ISO 4762, A2-70
M4; ISO 4762, A2-70
Screwing depth min. 10 mm