Page 52
Setting Sensor Parameters
optoNCDT 1900 / EtherCAT
7.4.5
Exposure Mode
Exposure
mode
Automatic mode
Standard /
Intelligent control /
Background suppression
0
50
0
95
50 Range in % 100
Intensity in
%
Standard: The sensor itself determines the optimal exposure time.
The sensor adjusts the signal intensity to approx. 50%.
Intelligent control: This intelligent algorithm is particularly advan-
tageous for measurements on moving objects or in the case of
transitions between different materials.
Background suppression: Suppresses interference caused by
ambient light. This significantly improves the ambient light toler-
ance of the sensor. The output rate of the sensor is halved.
Manuel mode
Exposure time
in µs
Value
In manual mode, with the video signal shown, the exposure time
is set by the user. Vary the exposure time in order to obtain a
signal intensity of up to 95%.
Fields with gray background require a selection.
Value
Fields with dark border require entry of a value
Summary of Contents for ILD1900-10