Page 67
EtherCAT
optoNCDT 1900 / EtherCAT
8.
EtherCAT
8.1
Preliminary Remarks
The sensors start with the last stored operating mode. Standard is EtherCAT.
The Ethernet setup mode enables, just like EoE, easy programming of a sensor, see Chap.
.
8.2
Saving the Settings, Continuing EtherCAT Operation
Go to
Settings > System settings > Load & Save
or click the
Save settings
button
.
The sensor now also saves the settings to the SD objects for use in EtherCAT operation.
Go to
Settings > System settings > Boot mode
. Select the entry
Industrial Ethernet
(EtherCAT).
The sensor disconnects from the browser and boots automatically with the EtherCAT firmware. The boot process can take up to one
minute.
Alternatively, you can return to the EtherCAT operation via the
Select
button. Details can be found in section
Switch between
Ethernet Setup Mode and EtherCAT,
A 4.
Continue working in your PLC environment.