Page 87
Appendix | EtherCAT Documentation
optoNCDT 1900 / EtherCAT
A 5.3.2
Manufacturer Specific Objects
Overview
Index (h) Name
Description
3000
Laser power
Laser light source
3200
Data recording
Measuring program such as measuring rate and peak selection
3400
Signal processing peak 1
Measurement averaging
3450
Mastering
Zeroing and Mastering
3800
System settings
Systems settings such as login and factory settings
3850
Device settings
Definition of measurement task
3851
Preset settings
Definition of signal quality
3852
Measurement settings
Load, save
3900
Sensor information
Information on measuring range and option of sensor
6000
Out_shutter
Output value exposure time
...
6008
Out_01_peak1_distance
Output value peak distance
The following is a description of the individual objects with their sub-indices. A description of the functionality of the sensor parameters
can be found in the corresponding sections of the operating instructions for the sensor.
Summary of Contents for ILD1900-10
Page 8: ...optoNCDT 1900 EtherCAT ...
Page 110: ...Page 110 Appendix EtherCAT Documentation optoNCDT 1900 EtherCAT ...
Page 111: ......