A 5.3.2.2
Object 3200: Measurement Configuration, Measuring Rate, Evaluation Range, Exposure, Peak Selection, Error
Handling
3200
RECORD Data recording
Subindices
0
VAR
Number of entries
1
UINT8
ro
1
VAR
Measurement task
x
UINT8
rw
3
VAR
Measuring rate
x
FLOAT
rw
0A
VAR
Start of range
x
UINT16
rw
0B
VAR
End of range
x
UINT16
rw
14
VAR
Shutter mode
x
UINT8
rw
15
VAR
Shutter time in us
x
FLOAT
rw
16
VAR
Exposure mode
x
UINT8
rw
1E
VAR
Peak selection
x
UINT8
rw
28
VAR
Error handling type
x
UINT8
rw
29
VAR
Error handling values
x
UINT32
rw
Measurement task: Shutter mode:
Exposure mode:
Peak selection
Error handling type
0 - Standard
0 - Manual
0 - Standard
0 - Highest peak
0 - None
1 - Multisurface
1 - Automatic
1 - Intelligent
1 - Widest peak
1 - Value
2 - Penetration
2 - Background
2 - Last peak
2 - Infinite
3 - First peak