Page 92
Appendix | EtherCAT Documentation
optoNCDT 1900 / EtherCAT
A 5.3.2.5
Object 3800: System Settings, Key Lock, Login, Password, Factory Settings
3800
RECORD System settings
Subindices
0
VAR
Number of entries
13
UINT8
ro
1
VAR
Key lock
x
UINT8
rw
2
VAR
Key lock countdown [min]
x
UINT8
rw
0B
VAR
Current access authorization
x
UINT8
ro
0C
VAR
Login
x
STRING(32)
wo
0D
VAR
Logout
x
BIT
rw
0E
VAR
User level when restarting
x
UINT8
rw
0F
VAR
Change password old
x
STRING(32)
wo
10
VAR
Change password new
x
STRING(32)
wo
11
VAR
Change password repeat
x
STRING(32)
wo
15
VAR
Reset to factory measurement settings
x
BIT
wo
16
VAR
Reset to factory device settings
x
BIT
wo
18
VAR
Reset to factory all settings
x
BIT
wo
19
VAR
Reboot sensor
x
BIT
wo
Current access
authorization
Logout
User level when
restarting
Reset to factory
measurement
settings
Reset to factory
device settings
Reset to factory
all settings
Reboot sensor
1 - User
0 - No
1 - User
0 - False
0 - False
0 - False
0 - False
3 - Professional
1 - Yes
2 - Professional
1 - True
1 - True
1 - True
1 - True
4 - Profe
Summary of Contents for ILD1900-10
Page 8: ...optoNCDT 1900 EtherCAT ...
Page 110: ...Page 110 Appendix EtherCAT Documentation optoNCDT 1900 EtherCAT ...
Page 111: ......