Operation
induSENSOR DTD / MSC7xxx
5.3.3
Sensor Parameters
LED D2 = red flashing
With this function, you can set the parameters
- sensor type,
- supply frequency and
- excitation voltage
if the automatic recognition is not successful, or for special areas of use other settings may be necessary.
These depend on the sensor model used. After manual setting of the sensor parameters, the adjustment of
the system
, is recommended.
Sensor model
Measuring
range
Sensor
type
Supply frequen-
cy
Excitation voltage
DTA-1x
±1 mm
LVDT
5 kHz
550 mV
DTA-3x
±3 mm
5 kHz
DTA-5x
±5 mm
5 kHz
DTA-10x
±10 mm
2 kHz
DTA-15x
±15 mm
1 kHz
DTA-25x
±25 mm
1 kHz
LDR-10
10 mm
LDR
21 kHz
LDR-25
25 mm
13 kHz
LDR-50
50 mm
9 kHz
LVP-3
3 mm
18 kHz
LDR-14
With 8 mm drawbar
14 mm
23 kHz
With 10 mm drawbar
23 kHz
LVP-25
With 8 mm drawbar
25 mm
16 kHz
With 10 mm drawbar
16 kHz
Fig. 53 Sensor models and sensor parameters