Page 32
Installation and Assembly
induSENSOR DTD / MSC7xxx
4.4.3
Sensor
The output signal increases, when the plunger is moved into the sensor. If the reverse effective direction is
required (i.e. the signal becomes smaller when the plunger is inserted), replace the connections
Sec and Secondary -.
Sensor pin
assignment (DTA/LVDT)
Variant with
cable gland
X2
1
2
3
4
5
6
Connector
1
2
3
4
5
5-pin housing socket M9
(Binder, series 712)
View on pin side
Assignment
Pin X2
DTA-x-CA-x
DTA-x-CR-x
Cable C701-x
DTA-x-CA-x DTA-xG8-x 5-pin
Shield
1
Shield
-
Shield
Housing
Secondary center tap
2
Gray
Gray
Gray
5
Sec
3
White
White
Black
1
Secondary -
4
Brown
Black
White
2
P
5
Green
Green
Blue
3
Primary -
6
Yellow
Yellow
Brown
4