Page 15
Installation and Assembly
MSC7401 Miniature sensor controller for inductive sensors
Wiring
The housing has to be opened in order to connect the sensors, see Chap.
4.3.2
, and wire the output and
supply cable, see Chap.
4.3.1
.
Loosen the screws.
Pass the sensor and signal cables through the cable glands.
Connect the cables to the screw terminals according to the pin assignments.
Magnetic core
Plunger
Secondary coil +
Secondary coil -
Center tab
Primary coil -
Primary coil +
Shield sensor cable
Fig. 5 Pin assignment for sensor on the terminal block X2, full bridge
Terminal block X2
Coil
Cable
1
DTA-x-CA-x
DTA-x-CR-
xC701-x
Wire
1
DTA-x-LA-x
Solder pin
1
DTA-x-TA-x
Cable
1
DTA-xG8-x
Secondary coil +
Pin 3
Secondary
white
white
1
black
Secondary coil -
Pin 4
brown
black
2
white
Center tap
Pin 2
gray
gray
5
gray
Primary coil -
Pin 6
Primary
yellow
yellow
4
brown
Primary coil +
Pin 5
green
green
3
blue
Shield sensor cable Pin 1
Shield
Shield
Fig. 6 Table for the pin assignment for the sensor at the terminal block X2, full bridge
1) The colors and pins listed apply to MICRO-EPSILON displacement sensors.