Page 29
Operation
MSC7401 Miniature sensor controller for inductive sensors
5.4.1
2-Point Adjustment
D1:
Channel
D2:
E1
D3:
E2
D4:
Value
G
G
R
Move the measuring object to the position X
1
and
change the output signal U
1
with
LED color changes
depending on the
target position.
O
Flashes orange,
when the measu-
ring object is in the
electrical center of
the sensor.
ENTER
G
R
LED color changes
depending on the
target position.
O
Move the measuring object to the position X
2
1
and change the output signal U
2
with
Flashes orange,
when the measu-
ring object is in the
electrical center of
the sensor.
Fig. 21 Menu structure controller MSC 7401, Adjustment mode: 2-point adjustment
1) Position X
2
must be > 10 % of the measuring range from X
1
.