Assembly Instructions
optoNCDT 1700
Proper Use
The optoNCDT1700 is designed for use in industrial areas. It is used for measuring displacement,
distance, position and elongation for in-process quality control and dimensional testing.
The sensor may only be operated within the limits specified in the technical data, see instruction
manual, Chap. 3.4. The sensor should only be used in such a way that in case of malfunctions or
failure personnel or machinery are not endangered. Additional precautions for safety and damage
prevention must be taken for safety-related applications.
Warnings
Connect the power supply in accordance to the safety regulations for electrical equipment. The
power supply may not exceed the specified limits.
> Danger of injury, damage to or destruction of the sensor
Avoid continuous exposure to spray on the sensor. Avoid exposure to aggressive materials (washing
agent, penetrating liquids or similar) on the sensor. Mount the sensor only to the existing holes on a
flat surface. Clamps of any kind are not permitted.
> Damage to or destruction of the sensor
Avoid shock and vibration to the sensor. Protect sensor cable against damage.
> Damage to or destruction of the system, failure of the measuring device
Laser Class
The optoNCDT1700 sensors operate with a semiconductor laser with a wavelength of 670 nm (visi-
ble/red, ILD 1700) respectively 405 nm (visible/blue, ILD 1700BL).
The following warning labels are attached to the cover (front and/or rear side) of the sensor housing:
LASER RADIATION
Do not stare into the beam
CLASS 2 LASER PRODUCT
IEC 60825-1: 2015-07
P≤1 mW;
λ
= 670 nm
LASER RADIATION
Do not stare into the beam
CLASS 2 LASER PRODUCT
IEC 60825-1: 2015-07
P≤1 mW;
λ
= 405 nm
IEC label
Only for USA
IEC label for ILD1700-x BL only
Never deliberately look into the laser beam! Consciously close your eyes or
turn away immediately if ever the laser beam should hit your eyes.
Inputs and Outputs
Pin Designation
Comment
Sensor cable
PC1700-x
5
+U
B
Power supply (11 ... 30 VDC)
red
6
GND
System ground for power supply and
switching signals (Laser on/off, Zero,
Limits)
black
13
Analog output
Current 4 ... 20 mA or
voltage 0 ... 10 V
Coaxial inner conductor, white
14
AGND
Reference potential for analog output
Coaxial screening
9
Laser on/off
Switching input laser on /off
red-blue
10
Zero
Switching input setting mid-point
white-green
8
Switching output 1 Error or limit output
gray-pink
7
Switching output 2 Limit output
violet
3
4
Sync +
1
Sync
-
1
Symmetrical synchron output
(Master) or input (Slave)
blue
pink
1
2
Tx +
Tx -
RS422 - output (symmetrical)
green
brown
12
11
Rx +
Rx -
RS422 - input (symmetrical)
gray
yellow
1) Used as trigger inputs in mode „Triggering“.
Plug connector: ODU MINI-SNAP, 14-pin, series B, dimension 2,
code 0, IP 68; www.odu.de
View on solder-pin side male cable connector, insulator
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Power Supply
,
nominal value: 24 VDC (11 ... 30 V, max. 150 mA).
ILD 1700
5
6
11 ...
30 VDC
Sensor
pin
PC1700-x
color
Power
supply
Use power supply only for measurement
devices. MICRO-EPSILON recommends
the use of the optional available power
supply PS2020 for the sensor.
5
red
+U
B
6
black
GND
Switching Inputs Laser On/Off, Setting Masters and Mid-point
ILD 1700
U
N-channel Relais/
switch
9 (10)
6
Open-
Collector
int
U
L
U
0.2 V
L
I
0.5 mA
L
I
L
X9771139-A071037MSC
MICRO-EPSILON MESSTECHNIK
GmbH & Co. KG
Königbacher Str. 15
·
94496 Ortenburg
www.micro-epsilon.com
*X9771139-A06*
The switching inputs for laser on/off and
setting masters/mid-point are similarly
wired. Connect pin 9 with pin 6 in order
to activate the laser. If the connection is
released, the laser is deactivated.
Membrane Keys, LED‘s
Measurement mode
(normal operation):
-
zero
key:
Sets the analog output to the value for the midrange, i.e. 5 VDC or
12 mA.
Pressing the
zero
key again resets the function.
-
function
key:
Switches the sensor to setup mode.
Pressing and holding the
function/enter
key for longer than 5 se-
conds, overwrites all the parameter values with the factory settings (default
values).
Setup mode
(
function
key actuated):
-
function
key:
For running through the levels and parameters.
-
select
key:
To open the selection list and
select the value of the parameter in sequence.
-
enter
key:
For saving the selected parameter value and
returning to measurement mode.
If approximately 15 seconds have elapsed since the last press of the
function
key or
30 seconds since the last press of the
select
key, the sensor returns to measurement mode
without changing the parameters.
LED
Status
Measurement mode
Setup mode
state
illuminated
Object is in the measurement
range or error
...
off
Sensor off or laser off
flashes slowly
...
Selected parameter value matches the
saved value
flashes quickly
...
Selected parameter value does not
match the saved value
output
speed
avg
illuminated or
flashing
Indication of the parameter values
level 1
Selected parameter value
flashing red
Status „off“
zero
illuminated
Sensor „master“ or „set to mid-point“
off
Normal operation
flashing
Sensor as slave without synchronous signal
In case of bore holes, blind holes and
edges in the surface of moving targets
the sensor must be arranged in such a
way that the edges do not obscure the
laser spot.
Correct
Incorrect
(shadow)
Dimensional Drawing and Free Space,
Measuring Ranges 2/10/20/50/100/200/250VT mm
Measuring Ranges 20/200BL
ILD 1700-2/10/20/50/100/200/250VT
ILD1700-2/10/20/50LL
ILD 1700-20/200BL
A
B
ø 4
(dia .16)
ø 8
(.31 dia)
15
(.59)
SMR
MR
80 (3.15)
89 (3.50)
97 (3.82)
30
(1.18)
15
(.59)
24.2
(.95)
36.1
(1.42)
67 (2.63)
4
75 (2.95)
37.5
(1.48)
Mounting holes
3 x ø4.5 (.18 dia.)
13.4 (.53)
13.2
(.52)
MR = Measuring range
SMR = Start of measuring range
MMR = Midrange
EMR = End of measuring range
MR
SMR
a
e
A
B
2
24
35.0 ° 44.8 ° 25.8 16.8
10
30
34.3 ° 35.6 ° 28.7 20.5
20
40
28.8 ° 26.7 ° 30.1 22.0
50
45
26.5 ° 18.3 ° 31.5 22.5
100
70
19.0 ° 10.9 ° 32.6 24.1
200
70
19.0 °
7.0 °
33.1 24.1
250VT
70
19.0 °
6.0 °
33.5 24.1
20BL
40
28.8 ° 26.7 ° 30.1 22.0
200BL
100
13.5 °
6.3 °
33.1 24.1
Proper Environment
- Protection class:
IP 65 (only with sensor cable connected)
Lenses are excluded from protection class. Contamination of the lenses leads to impairment or
failure of the function.
- Operating temperature: 0 ... 50 °C (+32 up to +122 °F)
- Storage temperature:
-20 ... 70 °C (-4 up to +158 °F)
- Humidity:
5 - 95 % (no condensation)
- Ambient pressure:
Atmospheric pressure
Sensor Mounting
The sensors of the series
optoNCDT 1700 are optical sen-
sors with which is measured in
the μm area.
i
Make sure that mounting
and operation is handled
carefully!
Mount the sensors with
three screws type M4. The
bearing surfaces surround-
ing the fastening holes
(through holes) are slightly
raised.
Dimensions in mm (inches), not to scale