Quick Guide
Components, Typical Application with Analog Output
PC1700-x
Target
PS2020
SPS
230 VAC
PE
N
L
A
D
4 ... 20 mA
0 ... 10 V
Laser On/Off
laser off
error
o.k.
midrange
normal
zero
4 - 20 mA
0 - 10 V
RS 422
1
1/2
1/4
1/8
1
4
32
128
opto
NCDT
Components, Typical Application with RS422 and IF2008
PC1700-x/IF2008
Target
laser off
error
o.k.
midrange
normal
zero
4 - 20 mA
0 - 10 V
RS 422
1
1/2
1/4
1/8
1
4
32
128
opto
NCDT
IF2008
Switching on the Power Supply Respectively PC
Switch on power supply respectively PC after completion of wiring.
The initialization including the info string transmission takes up to 10 seconds. Within this period,
the sensor neither executes nor replies commands.
To be able to produce reproducible measurements the sensor typically requires a start-up time of
20 minutes.
Change Measurement Value Output
Change the output type with the
function/enter
and
select/zero
keys.
Measurement
mode
Current output
4 ... 20 mA
Voltage output
0 ... 10 VDC
RS422
LED state
flashes green
red (flashes)
LED output
red
green
Save
parameters
function
enter
select
zero
select
zero
select
zero
select
zero
function
enter
Measurement value
mode
Place Target
Place the target in the midrange, if possible.
SMR
Target
Measuring range (MR)
Digital value
20 mA
4 mA
3 mA
Analog
output
161
0
16372
16207 16367 16374
MBA
EMR
Displacement
10.2 V
10 V
0 V
-0.1 V
laser off
er
ror
o.k.
midrange
nor
mal
zero
4 - 20 mA
0 - 10 V
RS 422
1
1/2
1/4
1/8
1
4
32
128
opto
NCDT
The State LED on sensor indicates the position of target to the sensor.
LED
Color
Meaning
State
off
Laser beam is switched off.
green Sensor in operation, target in measuring range
yellow Target is in midrange.
red
Target out of range, too low reflection
Operating Mode
Change the operating mode of the sensor.
Error-Mode
(error control, factory setting)
Switching output 1 Switching output 2
Measurement value
EMR
+
GND
+
GND
Switching output 1
Switching output 2
SMR
Time
Error output
inactive
The switching output 1 is activated
(conducting to GND),
- when the target is outside the mea-
suring range,
- there is no target present
- or if the target is unsuitable (too
dark, polished metal, insufficiently
reflective).
Function
- Setting mid-point
- No limit control
Switch-Mode
(limit control)
Switching output 1 Switching output 2
Measurement value
UL
UH
LH
LL
+
GND
+
GND
+
GND
+
GND
Switching output 1
Switching output 2
Switching output 1
Switching output 2
SET_UPPERLIMIT F1
SET_LOWERLIMIT F1
EMR
SMR
Time
Limit value
Limit value
The switching outputs are activated
(conducting to GND),
- when the target is outside the
measuring range,
- there is no target present
- or if a target is unsuitable (too
dark, polished metal, insufficiently
reflective).
The following 4 values are used:
- Upper limit (UL), --
- Lower limit (LL), --
- Upper hysteresis value (UH), --
- Lower hysteresis value (LH).
Function
- Mastering
- Limit control
Please refer to the instruction manual for factory settings to the limit and hysteresis values.
Switching Outputs
+24 VDC
T
ILD1700
Switching output 1/2
Pin 7 / 8
GND Pin 6
max. 100 mA
+U Pin 5
B
The transistor T is conductive in the
active state. The switching outputs are
short-circuit-proof.
To reset the short-circuit protection:
- Clear the external short circuit,
- switch off the sensor and switch on
again or
- send the software command „Reset“
to the sensor.
The two limit outputs may also be actu-
ated in parallel as window comparator
(OK/Not OK separation).
You will find informations on display and signal processing units online at: www.micro-epsilon.
com/accessories/index.html.
You can read more information about the sensor in the instruction manual. You will find these on-
line at www.micro-epsilon.de/download/manuals/man--optoNCDT-1700--en.pdf or on the delivered
CD.
- Power supply sensor
- Synchronization sensors
- Laser on/off
is done by the interface card