Quick Guide
Components
- Sensor
- Power supply
- Laptop / PC + USB/Ethernet a Ethernet cable
Mount the sensor and connect the components together.
Ethernet Connection
PC2300-0,5/Y
PC2300-x/SUB-D
Patch cable
NCDT
PS2020
230 VAC
PE
N
L
PS2020
Measuring object
opto
ERR
Power on
RUN
EtherCAT Ethernet
Laser off
In range
Midrange
Error
LASER RADIATION
Do not stare into beam
Class 2 Laser Product
IEC 60825-1: 2015-07
1mW; P
1.2mW; t=0.5...542 µs
P
P0
≤
≤
F=1.5...50kHz;
=670nm
EtherCAT Connection
PC2300-0,5/Y
PC2300-x/SUB-D
PS2020
230 VAC
PE
N
L
PS2020
Measuring object
NCDT
opto
ERR
Power on
RUN
EtherCAT Ethernet
Laser off
In range
Midrange
Error
Run
BECKHOFF
EK1122
X1
X2
Patch cable
LASER RADIATION
Do not stare into beam
Class 2 Laser Product
IEC 60825-1: 2015-07
P
1mW; P
1.2mW; t=0.5...542 s
0
P
≤
≤
μ
F=1.5...50kHz;
=670nm
Commissioning
The sensor is delivered ex factory with the IP address
169.254.168.150.
You can check the IP address of the sensors, that are connected
to a PC / network, with the
SensorFinder.exe. program. You will find this program on the
provided CD.
Now start the program SensorFinder.exe and click on the
button
Start scan
.
Select the designated sensor from the list.
Click the button
Start
browser
to connect the
sensor with your default
browser.
Alternatively: If DHCP is
enabled and the DHCP
server is linked with the DNS
server, an access is possible
on „ILD2300_SN01234567“
(„01234567“ Serial number of
your sensor).
Start a web browser on your PC. Type
„ILD2300_Serial number“ in the address bar of
your web browser.
Interactive websites for programming the sensor
now appear in the web browser.
If you have changed any settings, go to the
menu
Preferences
and click on the button
Save Setup
to store your settings.
Select a Measuring Program
Go to the menu
Preferences > Measuring program
.
Select
Diffuse reflection
from the measurement arrangement list. Confirm with
Apply
.
Select a Measuring Rate
Go to the menu
Preferences > Measuring rate
.
Start with a medium measuring rate. Select a measuring rate from the list. Confirm with
Apply
.
Select a Digital Interface
Go to the menu
Preferences > Digital interfaces > Selection of digital
interfaces
.
Select
Web Diagram
from the list. Confirm with
Apply
.
Store the Settings
Go to the menu
Preferences > Load/save settings
.
Select
Parameter set
from the data selection list, a parameter set number and click on the
button
Save
.
Position a Measuring Object
Position a measuring object (target) as possible in the midrange.
100 %
50
0
SMR
SMR MMR EMR
Displacement
Signal
NCDT
opto
ERR
Power on
RUN
EtherC
AT
Ethernet
Laser off
In range
Midrange
Er
ror
Measuring object
Measuring range
LASER RADIA
TION
Do not stare into beam Class 2 Laser Product
IEC 60
82
5-1: 201
5-0
7
P
1mW
; P
1.2
mW
; t=0.5...5
42
s
0
P
≤
≤
μ
F=1.5...5
0kHz;
=67
0nm
The Status LED Status on the sensor indicates the position of the measuring object to the sensor.
LED
Color
Labeling
Meaning
Status
off
Laser off
Laser beam is switched off
green In range
Sensor operates, measuring object within measuring range
yellow Midrange
Measuring object is in midrange
red
Error
Measuring object outside measuring range,
reflection is to low
Displacement Measuring
Go to the menu
Measurement
.
Disable the
Autoscale
function and click on the
Start
button.
Thickness Measurement
Got to the menu
Preferences > Measuring program
and select
Direct reflec-
tion - thickness measurement
from the measurement arrangement list.
Select the target material from the material list. Confirm with
Apply
.
Store the Settings
Go to the menu
Preferences > Load/save settings
.
Select
Parameter set
from the data selection list, a parameter set number and click on
the button
Save
.
Read the detailed instruction manual before using the sensor. The manual is available online on
www.micro-epsilon.com/download/manuals/man--optoNCDT-2300--en.pdf or on the supplied
CD.
Diffuse Reflection, Dimensions for Measuring Range 40, 200 and 300 mm
MR
40
200
300
SMR
175
130
200
MR
195
230
350
EMR
215
330
500
a
22.1 °
25.1 °
18.3 °
j
21.9 °
16.7 °
12.2 °
e
21.8 °
13.1 °
9.6 °
A
101
91.6
99.4 °
B
86
76.0
81
Start of measuring range
End of measuring range
SMR
MR
150 (5.90)
80 (3.15) 70 (2.76)
140 (5.51)
130 (5.52)
15 (.59)
12 (.47)
17.5 (.69)
35 (1.38)
A
B
3 x mounting
hole ø4.5
(.18 dia.)
ø5 (1.20 dia.)