WARRANTY

All power packs carry a full warranty against defects in material and workmanship for a period of eighteen (18) months on 

parts and one (1) year on labor.The compressor is warrantied for an additional three and one-half (3 1/2) years. All loss of 

sales must be borne by the purchaser.

WARRANTY CLAIMS PROCEDURE:

Purchaser shall notify Micro Matic of any defect discovered in the Product during the Warranty Period, and obtain a return 

authorization number. Purchaser must ship the Product per Micro Matic’s instruction. After receipt of the Product, Micro 

Matic shall, at its option, repair (or authorize the repair of), or replace or refund the purchase price for the Products found by 

Micro Matic to be defective. Micro Matic’s determination of defects is final. Failure by Purchaser to give notice of claims of 

breach of warranty within the Warranty Period shall be deemed an absolute and unconditional waiver of Purchaser’s claim 

for such defects. Products repaired or replaced during the Warranty Period shall be covered by the foregoing warranties 

for the remainder of the original Warranty Period or ninety (90) days from the date of delivery of the repaired or replaced 

Products, whichever is longer.

ALL REPAIRS MUST BE FIRST AUTHORIZED BY MICRO MATIC PER THE ABOVE PROCEDURE. UNAUTHORIZED REPAIRS 

WILL NOT BE REIMBURSED BY MICRO MATIC UNDER ANY CIRCUMSTANCES.

Micro Matic is not responsible for parts damaged from factors including, but not limited to any part that has been subject 

to misuse, neglect, alteration, accident, unauthorized service, abuse, or to any damage caused by transportation. This 

warranty does not cover items subject to normal wear and tear (gaskets, seals, o-rings, etc.). 

PURCHASER RESPONSIBILITY:

Except as expressly provided in this Agreement, Purchaser assumes all other responsibility for any loss, damage, or injury 

to persons or property arising out of, connected with, or resulting from the use of Products, either alone or in combination 

with other products or components. In no event will Micro Matic be responsible for incidental, consequential or punitive 

damages of any kind, including without limitation, claims for loss of beer, loss of gas or loss of sales.

OTHER WARRANTIES DISCLAIMED:

These are the sole and exclusive warranties and conditions given by Micro Matic with respect to the products and services 

and are in lieu of and exclude all other warranties or conditions, express or implied, arising by operation of law or otherwise, 

including without limitation, warranties of merchantability, fitness for a particular purpose and non-infringement, whether 

or not the purpose or use has been disclosed to Micro Matic in specifications, drawings or otherwise, and whether or not 

Micro Matic’s products are specifically designed and/or manufactured by Micro Matic for purchaser’s use or purpose.

LIMITATION OF REMEDY:

Purchaser’s sole and exclusive remedy for breach of any warranty or condition under this Article IV shall be limited to the 

repair, correction or replacement, or refund of the purchase price paid in respect of the defective Products, unless the 

claim falls under the provisions of Section 6.2, in which case Purchaser may also claim damages in accordance with the 

terms of Section 6.2.

Summary of Contents for MMPP4301

Page 1: ... MMPP4302 WC MMPP4302 PKG MMPP4302 PKG WC MMPP4303 PKG MMPP4303 PKG WC MMPP4303 PKG 3 MMPP4305 PKG MMPP4305 PKG WC MMPP4305 PKG 3 MMPP4305 PKG WC3 MMPP4307 PKG MMPP4307 PKG WC MMPP4307 PKG 3 MMPP4307 PKG 3 WC MMPP4307 PKG 4 MMPP4307 PKG 4 WC POWER PACK SERVICE MANUAL v3 0 ...

Page 2: ...IC COM 866 327 4159 EQUIPMENT SPECIFICATIONS 3 INSTALLATION 8 MAINTENANCE 9 CHANGING GLYCOL PUMP 11 REPLACING MOTOR 12 REPLACING THERMOSTAT 12 TROUBLESHOOTING 13 SPARE PARTS 14 WIRING DIAGRAMS 15 WARRANTY INFORMATION 23 TABLE OF CONTENTS ...

Page 3: ...18 low 140 high 18 low 140 high 18 low 140 high 18 low 140 high Dimensions L x W x H Including pump s and motor s 26 12 x 17 12 x 21 56 30 x 18 x 27 75 30 x 18 x 28 75 30 x 18 x 27 75 30 x 18 x 28 75 Weight lbs 41 kg 90 lbs 55 kg 120 lbs 55 kg 120 lbs 58 kg 128 lbs 58 kg 128 lbs Bath Capacity gal 4 5 gal 17 L 11 5 gal 43 5 L 11 5 gal 43 5 L 11 5 gal 43 5 L 11 5 gal 43 5 L Bath Insulation Thickness...

Page 4: ...high 18 low 140 high 18 low 140 high 18 low 140 high 18 low 140 high Dimensions L x W x H Including pump s and motor s 30 x 18 x 29 75 30 x 18 x 28 75 30 x 18 x 29 75 30 x 18 x 28 75 30 x 18 x 29 75 Weight lbs 71 kg 157 lbs 80 kg 175 lbs 71 kg 157 lbs 71 kg 157 lbs 80 kg 175 lbs Bath Capacity gal 11 5 gal 43 5 L 11 5 gal 43 5 L 11 5 gal 43 5 L 11 5 gal 43 5 L 11 5 gal 43 5 L Bath Insulation Thickn...

Page 5: ...ow 140 high 18 low 140 high 18 low 140 high 18 low 140 high Dimensions L x W x H Including pump s and motor s 30 x 18 x 28 75 30 x 18 x 29 75 30 x 18 x 28 75 37 12 x 18 75 x 31 15 37 12 x 18 75 x 31 5 Weight lbs 80 kg 175 lbs 91 kg 200 lbs 80 kg 175 lbs 98 kg 215 lbs 98 kg 215 lbs Bath Capacity gal 11 5 gal 43 5 L 11 5 gal 43 5 L 11 5 gal 43 5 L 11 5 gal 43 5 L 11 5 gal 43 5 L Bath Insulation Thic...

Page 6: ... low 140 high 18 low 140 high 55 low 260 high 55 low 260 high 55 low 260 high Dimensions L x W x H Including pump s and motor s 37 12 x 18 75 x 31 5 37 12 x 28 75 x 31 5 38 x 20 x 36 37 12 x 18 75 x 31 5 38 x 30 x 36 Weight lbs 131 kg 290 lbs 98 kg 215 lbs 134 kg 295 lbs 134 kg 295 lbs 134 kg 295 lbs Bath Capacity gal 11 5 gal 43 5 L 11 5 gal 43 5 L 11 5 gal 43 5 L 11 5 gal 43 5 L 11 5 gal 43 5 L ...

Page 7: ... low 260 high 55 low 260 high Dimensions L x W x H Including pump s and motor s 37 12 x 18 75 x 31 5 38 x 30 x 36 37 12 x 28 75 x 31 5 Weight lbs 134 kg 295 lbs 134 kg 295 lbs 134 kg 295 lbs Bath Capacity gal 11 5 gal 43 5 L 11 5 gal 43 5 L 11 5 gal 43 5 L Bath Insulation Thickness 1 5 1 5 1 5 Inlet Water Pressure Min 40 psi Max 120 psi NA Min 40 psi Max 120 psi Water Inlet Outlet Fitting 9 52mm 3...

Page 8: ...ions are complete 1 Connect one of the glycol tubes to the pump inlet Insulate any exposed tubing 2 Connect the second glycol line to the pump outlet Insulate any exposed tubing 3 Carefully push the glycol bath lid to one side allowing sufficient space to fill the bath with liquid 4 Inspect the bath for debris 5 Fill the glycol bath with Micro Matic Polar Flo glycol solution mixed 2 parts water to...

Page 9: ...07 PKG 4 Mix 7 parts distilled water to 5 parts glycol Fill bath to the level of the fill line on the glycol level indicator 6 Replace the refrigeration deck 7 Connect electrical outlets capable of handling the required voltage loads This should be carried out by suitably trained personnel and must comply with all state and national codes 8 Glycol level will fall as glycol is pumped through the gl...

Page 10: ...inued 3 If there is evidence of ice build up in the unit allow the ice to melt and replace all the water glycol solution with a fresh solution mixed per above instructions 4 The glycol water solution should be changed approximately every 18 months In regions of high humidity considerations should be given to replacing the solution on an annual basis 5 Check and clean the condenser fins every sixty...

Page 11: ...4302 PKG MMPP4302 PKG WC MMPP4303 PKG MMPP4303 PKG WC MMPP4303 PKG 3 MMPP4305 PKG MMPP4305 PKG WC MMPP4305 PKG 3 MMPP4305 PKG WC3 MMPP4307 PKG MMPP4307 PKG WC MMPP4307 PKG 3 MMPP4307 PKG 3 WC MMPP4307 PKG 4 MMPP4307 PKG 4 WC Note A pinch off tool is required to complete this repair 1 Unplug unit from receptacle 2 Pinch off glycol supply line to bottom of pump allowing enough room to remove clamp s...

Page 12: ...rd to new motor by affixing ground wire to green ground screw and plugging 2 wires to motor connections Place cord in electrical wire channel in motor housing and reattach electrical connection cover plate 8 Plug cord into receptacle REPLACING THERMOSTAT IN ALL UNITS 1 Unplug unit from receptacle 2 Remove the screws holding the thermostat housing to the unit Slide the white plastic brackets backwa...

Page 13: ...ressor malfunction C Replace compressor 5 Warm beer A Defective Pump check motor also A Check return line in reservoir for liquid flow Replace pump on 125 250 and 500 units Check condition of key between pump and motor B Defective motor check pump also B Replace motor C Refrigeration unit not running C Refer to 2 D Trunk lines located in overheated area D Remove from any hot water pipes or kitchen...

Page 14: ...MMPP4305 M X X X Vane Pump Key MM 3362 2 X X X X X Clamp Pump Connectors MM BC3 KIT X X X X X Nipple for Vane Pump Straight 617C X X X X X Vertical Pump MMPP4301 EPVP X Thermostat Danfoss ERC 112C MMPP080G3206 X X X X X X Compressor MPP4301 Series MMPP4301 EP C X X Refrigeration Deck MPP4301 Series MMPP4301 UPPER X Refrigeration Deck MPP4302 Series MMPP4302 UPPER X Compressor MPP4302 Series MMPP43...

Page 15: ...MICROMATIC COM 866 327 4159 POWER PACK SERVICE MANUAL 15 WIRING DIAGRAMS MMPP4301 EP MMPP4301 ...

Page 16: ...16 POWER PACK SERVICE MANUAL MICROMATIC COM 866 327 4159 MMPP4301 PKG MMPP4302 ...

Page 17: ...MICROMATIC COM 866 327 4159 POWER PACK SERVICE MANUAL 17 MMPP4302 PKG MMPP4303 PKG ...

Page 18: ...18 POWER PACK SERVICE MANUAL MICROMATIC COM 866 327 4159 MMPP4303 PKG 3 MMPP4305 PKG ...

Page 19: ...MICROMATIC COM 866 327 4159 POWER PACK SERVICE MANUAL 19 MMPP4305 PKG 3 ...

Page 20: ...20 POWER PACK SERVICE MANUAL MICROMATIC COM 866 327 4159 MMPP4307 PKG MMPP4307 PKG 3 ...

Page 21: ...MICROMATIC COM 866 327 4159 POWER PACK SERVICE MANUAL 21 MMPP4307 PKG 4 ...

Page 22: ...22 POWER PACK SERVICE MANUAL MICROMATIC COM 866 327 4159 ...

Page 23: ...bject to misuse neglect alteration accident unauthorized service abuse or to any damage caused by transportation This warranty does not cover items subject to normal wear and tear gaskets seals o rings etc PURCHASER RESPONSIBILITY Except as expressly provided in this Agreement Purchaser assumes all other responsibility for any loss damage or injury to persons or property arising out of connected w...

Page 24: ...02035 MM M 0319 2019 Micro Matic USA Inc All Rights Reserved Micro Matic reserves the right to change specifications without notice ...

Reviews: