background image

Table of Contents

Introduction.....................................................................................................................................................1

Features.................................................................................................................................................. 1

1.  Standards and Safety Guidelines............................................................................................................3

1.1.  Part Number Definition................................................................................................................. 3
1.2.  Electrical Compatibility Approvals................................................................................................ 3
1.3.  Safety Standard Approvals...........................................................................................................3
1.4.  CE Marking...................................................................................................................................3
1.5.  GS Compliance............................................................................................................................ 3
1.6.  Surge/Lightening Protection......................................................................................................... 3
1.7.  Safety Information........................................................................................................................ 4

2.  Information en Matière de Sécurité......................................................................................................... 5

2.1.  Directives Générales.................................................................................................................... 5
2.2.  Mises en Garde............................................................................................................................ 5

3.  PoE Midspan Unit Installation (Outdoor Unit)......................................................................................... 6

3.1.  Parts List...................................................................................................................................... 6
3.2.  Additional Tools............................................................................................................................ 6
3.3.  Midspan Unit Installation.............................................................................................................. 7

4.  Installation of Cables.............................................................................................................................10

4.1.  AC Power Cable Installation.......................................................................................................10
4.2.  RJ45 Cable 

Installation

.............................................................................................................11

4.3.  Data and Power Connection...................................................................................................... 12

5.  Troubleshooting.....................................................................................................................................13

5.1.  Preliminary Steps....................................................................................................................... 13
5.2.  Troubleshooting Steps................................................................................................................13

6.  Specifications........................................................................................................................................ 14

6.1.  Environmental Specifications..................................................................................................... 14
6.2.  Electrical Specifications..............................................................................................................14
6.3.  Interface..................................................................................................................................... 14

7.  Technical Support..................................................................................................................................15

8.  Revision History.................................................................................................................................... 16

Microchip Information................................................................................................................................... 17

The Microchip Website..........................................................................................................................17
Product Change Notification Service.................................................................................................... 17
Customer Support................................................................................................................................. 17
Microchip Devices Code Protection Feature.........................................................................................17
Legal Notice.......................................................................................................................................... 17
Trademarks........................................................................................................................................... 18
Quality Management System................................................................................................................ 19
Worldwide Sales and Service................................................................................................................20

 PD-9501-xxGCO/AC

©

 2022 Microchip Technology Inc.

and its subsidiaries

 User Guide

DS50003340A-page 2

Summary of Contents for PD-9501-10GCO/AC

Page 1: ...rminal The PD 9501 xxGCO AC supports emerging wireless 10 Gbps devices such as wireless IEEE 802 11ac access points PoE midspan powers devices that are PoE enabled or equipped to receive PoE These devices are called powered devices PDs Features PoE Midspans offer the following key features Outdoor Rated IP66 and IP67 Extended Temperature Range 40 C to 65 C Supports 10 100 1000 Mbps and 2 5 5 10 Gb...

Page 2: ...stallation of Cables 10 4 1 AC Power Cable Installation 10 4 2 RJ45 Cable Installation 11 4 3 Data and Power Connection 12 5 Troubleshooting 13 5 1 Preliminary Steps 13 5 2 Troubleshooting Steps 13 6 Specifications 14 6 1 Environmental Specifications 14 6 2 Electrical Specifications 14 6 3 Interface 14 7 Technical Support 15 8 Revision History 16 Microchip Information 17 The Microchip Website 17 P...

Page 3: ...meets the following safety standards Consult Microchip for a complete list of safety certifications UL IEC EN62368 1 UL IEC EN60950 22 GS Compliance 1 4 CE Marking CE marking on this product indicates that this product complies with the Electromagnetic Compatibility EMC Directive 1 5 GS Compliance GS marking on this product indicates that the product complies with the German Product Safety Act 1 6...

Page 4: ...ismatch can damage the equipment and can pose a fire hazard If voltage indicated on the label is different from the power outlet voltage do not connect midspan unit to this outlet All wiring and connections must conform to NFPA 70 NEC Power supply cord must not be attached to the building surface or run through walls ceilings floors and similar openings in the building structure Measures must be t...

Page 5: ...Une disparité de voltage peut endommager l équipement et constituer un risque d incendie Si le voltage indiqué sur l étiquette est différent du voltage de la source d alimentation ne pas connecter le midspan à cette prise Tout le câblage et les connexions doivent être conformes à la norme NFPA 70 NEC Le cordon d alimentation ne doit pas être fixé à la surface du bâtiment ni passer à travers les mu...

Page 6: ... 3 Earth ground screw must be connected to earth ground in all types of installations 3 1 Parts List The following table lists the parts included in the kit Quantity Component 1 60W midspan unit outdoor model 1 AC female connector 1 Quick Installation Guide 3 2 Additional Tools The following table lists the additional tools required to install the midspan unit Quantity Part 1 Screwdriver 1 Wire st...

Page 7: ...er the midspan or block the airflow to the PoE with any foreign objects Keep the midspan away from excessive heat and free from vibration Ensure that the cable length from the Ethernet network source to the terminal does not exceed 100 meters 333 feet The midspan is not a repeater and does not amplify the Ethernet data signal The midspan has no ON OFF switch simply plug the midspan to an AC power ...

Page 8: ...to a wall 1 Using the screw holes of the midspan as a template put marks on the mounting surface a wall of wood brick or concrete to mark drill points and drill four holes 2 With the unit attached to the mounting surface insert four mounting screws through the screw holes on the unit and into the mounting surface For bricks or concrete wall use anchor screws 5 mm x 40 mm For wooden wall use wood s...

Page 9: ...screws and tighten the pan head screws to 1 1 Nm 2 Place the midspan pole bracket assembly onto the pole Tighten the midspan pole bracket assembly to the pole using worm clams as shown in the following figures Notes Pole bracket supports poles with diameters ranging from 60 mm to 200 mm 2 5 inches to 8 inches The unit must be installed with DATA IN and DATA PWR OUT ports facing down as shown in th...

Page 10: ...N F or H07RN F Voltage rating 300V or better recommended Temperature range 40 to 65 or better recommended Cable size 16 AWG 18 AWG 3C 1 0 mm2 1 5 mm2 3C Cable outer dimension Dia 3 16 in 3 8 in Dia 5 0 mm 9 5 mm Approved for indoor and outdoor applications The following figure shows how to connect the AC power cable to the midspan unit Figure 4 1 Connecting the AC Power Cable to the Unit PD 9501 x...

Page 11: ...d the upper cap towards the midspan and hand tighten the upper cap onto the DATA IN port Note Secure the gland until the rubber gasket is firmly closed around the cable 4 Repeat step 1 to step 3 to connect the RJ45 cable to the DATA PWR OUT port Notes 1 Use cable up to 5 Gig Cat 5e and above outdoor grade 2 Use cable up to 10 Gig Cat 6 and above outdoor grade PD 9501 xxGCO AC Installation of Cable...

Page 12: ...tem 3 in the following figure 3 Connect AC power lines from the LINE IN terminal item 1 in the following figure to main AC power Ensure that the power outlet is nearby and easily accessible Note Connect the midspan unit to a weather proof AC power source box that meets IP66 and IP67 ratings Label Description 1 LINE IN Power input 100 VAC 240 VAC 2 DATA IN Data in to the Ethernet network switch 3 D...

Page 13: ...VAC 240 VAC 3 Remove and reapply power to the device during power up sequence PD does not operate 1 Verify that the port is enabled midspan did not detect a PD 2 Verify that the PD is designed for PoE operation 3 Verify that you are using a standard Category 5 5e 6 straight wired cable with four pairs according to data rate 4 If an external power splitter is in use replace it with a viable splitte...

Page 14: ...power maximum 60W Nominal output voltage 54 VDC 6 3 Interface Table 6 3 Interface Parameter Type Input Data In Ethernet 10 100 1000Base T and up to 5G 10GBase T for the PD 9501 10GCO AC or up to 2 5GBase T for the PD 9501 25GCO AC RJ45 female socket Output DATA PWR OUT Ethernet 10 100 1000 and up to 5G 10GBase T for the PD 9501 10GCO AC or up to 2 5GBase T for the PD 9501 25GCO AC plus 54 VDC RJ45...

Page 15: ...consult the Microchip technical support team through the website or contact on the following number USA Canada Telephone 1 877 480 2323 Internet www microchip com support PD 9501 xxGCO AC Technical Support 2022 Microchip Technology Inc and its subsidiaries User Guide DS50003340A page 15 ...

Page 16: ...8 Revision History Revision Date Description A 06 2022 Initial revision PD 9501 xxGCO AC Revision History 2022 Microchip Technology Inc and its subsidiaries User Guide DS50003340A page 16 ...

Page 17: ...ributor representative or ESE for support Local sales offices are also available to help customers A listing of sales offices and locations is included in this document Technical support is available through the website at www microchip com support Microchip Devices Code Protection Feature Note the following details of the code protection feature on Microchip products Microchip products meet the s...

Page 18: ...ce tinyAVR UNI O Vectron and XMEGA are registered trademarks of Microchip Technology Incorporated in the U S A and other countries AgileSwitch APT ClockWorks The Embedded Control Solutions Company EtherSynch Flashtec Hyper Speed Control HyperLight Load IntelliMOS Libero motorBench mTouch Powermite 3 Precision Edge ProASIC ProASIC Plus ProASIC Plus logo Quiet Wire SmartFusion SyncWorld Temux TimeCe...

Page 19: ...ement System For information regarding Microchip s Quality Management Systems please visit www microchip com quality PD 9501 xxGCO AC 2022 Microchip Technology Inc and its subsidiaries User Guide DS50003340A page 19 ...

Page 20: ...amen Tel 86 592 2388138 China Zhuhai Tel 86 756 3210040 India Bangalore Tel 91 80 3090 4444 India New Delhi Tel 91 11 4160 8631 India Pune Tel 91 20 4121 0141 Japan Osaka Tel 81 6 6152 7160 Japan Tokyo Tel 81 3 6880 3770 Korea Daegu Tel 82 53 744 4301 Korea Seoul Tel 82 2 554 7200 Malaysia Kuala Lumpur Tel 60 3 7651 7906 Malaysia Penang Tel 60 4 227 8870 Philippines Manila Tel 63 2 634 9065 Singap...

Page 21: ...nd einen sicheren und zuverlässigen Betrieb in Außenumgebungen für Standard PoE Datenendgeräte gewährleistet Der PD 9501 xxGCO AC unterstützt neue drahtlose 10 Gbit s Geräte wie z B drahtlose IEEE 802 11ac Access Points Der PoE Midspan versorgt Geräte die PoE fähig oder für den Empfang von PoE ausgerüstet sind Diese Geräte werden als Powered Devices PDs bezeichnet Funktionen und Merkmale PoE Midsp...

Page 22: ...e 7 3 2 Zusätzliche Werkzeuge 7 3 3 Installation des Midspan Geräts 8 4 Installation der Kabel 11 4 1 AC Netzkabelinstallation 11 4 2 RJ45 Netzkabelinstallation 12 4 3 Daten und Stromanschluss 13 5 Fehlersuche 14 5 1 Vorläufige Schritte 14 5 2 Schritte zur Fehlersuche 14 6 Technische Daten 15 6 1 Umgebungsdaten 15 6 2 Elektrische Daten 15 6 3 Schnittstelle 15 7 Technischer Support 16 8 Überarbeitu...

Page 23: ...Quality Management System 20 Worldwide Sales and Service 21 PD 9501 xxGCO AC 2022 Microchip Technology Inc and its subsidiaries User Guide DS50003340A page 3 ...

Page 24: ...sstandards Wenden Sie sich an Microchip um eine vollständige Liste der Sicherheitszertifizierungen zu erhalten UL IEC EN62368 1 UL IEC EN60950 22 GS Übereinstimmung 1 4 CE Kennzeichnung Die CE Kennzeichnung auf diesem Produkt zeigt an dass dieses Produkt die Richtlinie zur elektromagnetischen Verträglichkeit EMV erfüllt 1 5 GS Übereinstimmung Das GS Zeichen auf diesem Produkt bedeutet dass das Pro...

Page 25: ...beschädigen und eine Brandgefahr darstellen Wenn die auf dem Etikett angegebene Spannung nicht mit der Spannung der Steckdose übereinstimmt darf das Midspan Gerät nicht an diese Steckdose angeschlossen werden Alle Verdrahtungen und Anschlüsse müssen der NFPA 70 NEC entsprechen Das Netzkabel darf nicht an der Oberfläche des Gebäudes befestigt werden oder durch Wände Decken Böden und ähnliche Öffnun...

Page 26: ...uipement Une disparité de voltage peut endommager l équipement et constituer un risque d incendie Si le voltage indiqué sur l étiquette est différent du voltage de la source d alimentation ne pas connecter le midspan à cette prise Tout le câblage et les connexions doivent être conformes à la norme NFPA 70 NEC Le cordon d alimentation ne doit pas être fixé à la surface du bâtiment ni passer à trave...

Page 27: ...egt 3 Die Erdungsschraube muss bei allen Installationsarten mit der Erdung verbunden werden 3 1 Teileliste In der folgenden Tabelle sind die im Kit enthaltenen Teile aufgeführt Menge Bauteil 1 60 W Midspan Gerät Modell für den Außenbereich 1 AC Buchse 1 Kurzanleitung zur Montage 3 2 Zusätzliche Werkzeuge In der folgenden Tabelle finden Sie die zusätzlichen Werkzeuge die für die Installation des Mi...

Page 28: ...en Sie den Midspan nicht ab und blockieren Sie den Luftstrom zum PoE nicht mit Fremdkörpern Halten Sie den Midspan fern von übermäßiger Hitze und frei von Vibrationen Stellen Sie sicher dass die Kabellänge von der Ethernetnetzwerkquelle bis zum Endgerät100 Meter 330 Fuß nicht überschreitet Dieser Midspan ist kein Repeater und verstärkt das Ethernetdatensignal nicht Der Midspan hat keinen EIN AUS S...

Page 29: ...blone markieren Sie die Bohrpunkte auf der Montageoberfläche eine Wand aus Holz Ziegel oder Beton und bohren Sie vier Löcher 2 Wenn das Gerät an der Montageoberfläche befestigt ist führen Sie vier Montageschrauben durch die Schrauböffnungen am Gerät und in die Montageoberfläche ein Verwenden Sie für eine Ziegel oder Betonwand Dübel mit Schrauben mindestens 5 mm x 40 mm Verwenden Sie für eine Holzw...

Page 30: ...hrauben auf 1 1 Nm an 2 Setzen Sie die Midspan Masthalterungsbaugruppe auf den Mast Ziehen Sie die Midspan Masthalterungsbaugruppe mit Schneckenschrauben am Mast fest wie in den folgenden Abbildungen gezeigt Anmerkungen Die Masthalterung unterstützt Masten mit einem Durchmesser von 60 mm bis 200 mm 2 5 Zoll bis 8 Zoll Das Gerät muss so installiert werden dass die Dateneingangs und Datenausgangs so...

Page 31: ...oder H07RN F Nennspannung 300V oder besser wird empfohlen Temperaturbereich 40 bis 65 oder besser wird empfohlen Kabelgröße 16 AWG 18 AWG 3C 1 0 mm2 1 5 mm2 3C Kabelaußenmaße Durchm 3 16 Zoll 3 8 Zoll Durchm 5 0 mm 9 5 mm Zugelassen für Anwendungen im Innen und Außenbereich Die folgende Abbildung zeigt wie das AC Netzkabel an die Midspan Einheit angeschlossen wird Abbildung 4 1 Anschließen des AC ...

Page 32: ...appe in Richtung Midspan und ziehen Sie die obere Kappe am Dateneingangs Port DATA IN handfest an Anmerkung Sichern Sie die Verschraubung bis die Gummidichtung fest um das Kabel geschlossen ist 4 Wiederholen Sie Schritt 1 bis Schritt 3 um das RJ45 Kabel an den Daten und PWR Ausgangs Port Data und PWR OUT anzuschließen Anmerkungen 1 Verwenden Sie Kabel bis zu 5 Gig Cat 5e und darüber für den Außenb...

Page 33: ...ten Ethernet Netzwerk Element 3 in der folgenden Abbildung 3 Verbinden Sie die AC Stromleitungen vom LINE IN Anschluss Element 1 in der folgenden Abbildung mit dem AC Netzstrom Stellen Sie sicher dass die Steckdose in der Nähe und leicht zugänglich ist Anmerkung Schließen Sie das Midspan Gerät an eine wetterfeste AC Stromquelle an die den Schutzklassen IP66 und IP67 entspricht Etikett Beschreibung...

Page 34: ...ng verbinden Sie es erneut während des Einschaltvorgangs PD funktioniert nicht 1 Stellen Sie sicher dass der Port aktiviert ist der Midspan hat keinen PD erkannt 2 Stellen Sie sicher dass der PD für den PoE Betrieb ausgelegt ist 3 Stellen Sie sicher dass Sie ein gerade verdrahtetes Standardkabel der Kategorie 5 5e 6 mit vier Paaren je nach Datenrate verwenden 4 Falls ein externer Stromsplitter ver...

Page 35: ...0 W Nennausgangsspannung 54 VDC 6 3 Schnittstelle Tabelle 6 3 Schnittstelle Parameter Typ Eingang Data In Ethernet 10 100 1000Base T und bis zu 5G 10GBase T für den PD 9501 10GCO AC oder bis zu 2 5GBase T für den PD 9501 25GCO AC RJ45 Buchse Ausgang DATA PWR OUT Ethernet 10 100 1000 und bis zu 5G 10GBase T für den PD 9501 10GCO AC oder bis zu 2 5GBase T für den PD 9501 25GCO AC plus 54 VDC RJ45 Bu...

Page 36: ...eten wenden Sie sich an den technischen Support von Microchip über die Webseite oder unter der folgenden Nummer USA Kanada Telefon 1 877 480 2323 Internet www microchip com support PD 9501 xxGCO AC Technischer Support 2022 Microchip Technology Inc and its subsidiaries User Guide DS50003340A page 16 ...

Page 37: ...rarbeitungsübersicht Überarbeitung Datum Beschreibung A 06 2022 Erste Überarbeitung PD 9501 xxGCO AC Überarbeitungsübersicht 2022 Microchip Technology Inc and its subsidiaries User Guide DS50003340A page 17 ...

Page 38: ...ncluded in this document Technical support is available through the website at www microchip com support Microchip Devices Code Protection Feature Note the following details of the code protection feature on Microchip products Microchip products meet the specifications contained in their particular Microchip Data Sheet Microchip believes that its family of products is secure when used in the inten...

Page 39: ...gileSwitch APT ClockWorks The Embedded Control Solutions Company EtherSynch Flashtec Hyper Speed Control HyperLight Load IntelliMOS Libero motorBench mTouch Powermite 3 Precision Edge ProASIC ProASIC Plus ProASIC Plus logo Quiet Wire SmartFusion SyncWorld Temux TimeCesium TimeHub TimePictra TimeProvider TrueTime WinPath and ZL are registered trademarks of Microchip Technology Incorporated in the U...

Page 40: ...ement System For information regarding Microchip s Quality Management Systems please visit www microchip com quality PD 9501 xxGCO AC 2022 Microchip Technology Inc and its subsidiaries User Guide DS50003340A page 20 ...

Page 41: ...amen Tel 86 592 2388138 China Zhuhai Tel 86 756 3210040 India Bangalore Tel 91 80 3090 4444 India New Delhi Tel 91 11 4160 8631 India Pune Tel 91 20 4121 0141 Japan Osaka Tel 81 6 6152 7160 Japan Tokyo Tel 81 3 6880 3770 Korea Daegu Tel 82 53 744 4301 Korea Seoul Tel 82 2 554 7200 Malaysia Kuala Lumpur Tel 60 3 7651 7906 Malaysia Penang Tel 60 4 227 8870 Philippines Manila Tel 63 2 634 9065 Singap...

Reviews: