MC2-30V
Doc. N°
MO-0499-ING
Copyright 2019
Date
17.03.2022
Rev.
2
Pag. 26
of
63
15.1 – Events on display
Functions
Events
Displayed
Events Description
Status
1U>
1U>
1U>
Start
First overvoltage element
Rise
t1U>
t1U>
Trip
Rise
Fall
2U>
2U>
2U>
Start
Second overvoltage element
Rise
t2U>
t2U>
Trip
Rise
Fall
1U<
1U<
1U<
Start
First undervoltage element
Rise
t1U<>
t1U<
Trip
Rise
Fall
2U<
2U<
2U<
Start
Second undervoltage element
Rise
t2U<
t2U<
Trip
Rise
Fall
1f>
1f>
1f>
Start
First overfrequency element
Rise
t1f>
t1f>
Trip
Rise
Fall
2f>
2f>
2f>
Start
Second overfrequency element
Rise
t2f>
t2f>
Trip
Rise
Fall
1f<
1f<
1f<
Start
First underfrequency element
Rise
t1f<
t1f<
Trip
Rise
Fall
2f<
2f<
2f<
Start
Second underfrequency element
Rise
t2f<
t2f<
Trip
Rise
Fall
1Uo>
1Uo>
1Uo>
Start
First zero sequence overvoltage element
Rise
t1Uo>
t1Uo>
Trip
Rise
Fall
2Uo>
2Uo>
2Uo>
Start
Second zero sequence overvoltage element
Rise
t2Uo>
t2Uo>
Trip
Rise
Fall
U1<
U1>
U1>
Start
First Voltmetric unlock islanding detector element
Rise
tU1>
tU1>
Trip
Rise
Fall
U2>
U2>
U2>
Start
Second Voltmetric unlock islanding detector element
Rise
tU1>
tU1>
Trip
Rise
Fall
1df/dt
1df/dt
1df/dt
Start
First Frequency rate of change
Rise
2df/dt
2df/dt
2df/dt
Start
Second Frequency rate of change
Rise
TCS
TCS
TCS
Start
Trip Coil Supervision
Rise
tTCS
tTCS
Trip
Rise
Fall
IRF
IRF
IRF
Start
Internal Relay Failure
Rise
tIRF
tIRF
Trip
Rise
TimeSincro
Time synchronization
Rise
Disk
DskClean
Disk near to full clean operation is required
Rise
DskFull
Disk full write should be lock
Rise
L/R disc
Local/Remote signal Discrepancy
Rise
rDskAttach
Not used
Removable disk usb attach
rDskDetach
Removable disk usb detach
rDskDtchable
Removable disk usb now detachable
rDskClean
Removable disk usb near to full clean operation is required
rDskFull
Removable disk usb full, write locked
C/B
manOpKey
Circuit Breaker intentional open by key
Rise
manOpLocC
Circuit Breaker intentional open by local command
Rise
manOpRemC
Circuit Breaker intentional open by remote command
Rise
manOpExtIn
Circuit Breaker intentional open by external input
Rise
ExterManOp
Circuit Breaker intentional external open
Rise
manClKey
Circuit Breaker intentional close by key
Rise
manClLocC
Circuit Breaker intentional close by local command
Rise
manClRemC
Circuit Breaker intentional close by remote command
Rise
manClExtIn
Circuit Breaker intentional close by external input
Rise
ExterManCh
Circuit Breaker intentional external close
Rise
CB-Fail
Circuit Breaker (C/B Failure)
Rise
Fall
CRCInChCB
Cycle blocked intentional CB Close
Rise
Charat 1
Switch to SetUp Group1
Rise
Fall
Charat 2
Switch to SetUp Group2
Rise
Fall
Charat 3
Switch to SetUp Group3
Rise
Fall
Charat 4
Switch to SetUp Group4
Rise
Fall
Gen.Trip
General Trip
Rise
Gen.Start
General Start
Rise
D
igi
ta
l
In
pu
ts
0.D1
Digital Input D1
Rise
Fall
↓
0.D8
Digital Input D8
Rise
Fall
O
u
tp
ut
R
el
ay
s
0.R1
Output relays R1
Rise
Fall
↓
0.R8
Output relays R8
Rise
Fall