background image

INSTALLATION & OPERATING INSTRUCTIONS

IIM

MP

PO

OR

RTTA

AN

NTT::  P

PLLEEA

ASSEE  R

REEA

AD

D  TTH

HEESSEE  IIN

NSSTTR

RU

UC

CTTIIO

ON

NSS  C

CA

AR

REEFFU

ULLLLYY  B

BEEFFO

OR

REE  A

ATTTTEEM

MP

PTTIIN

NG

G  TTO

O  IIN

NSSTTA

ALLLL  TTH

HIISS  A

ALLA

AR

RM

M  SSYYSSTTEEM

M..  

IIFF  TTH

HEE  SSYYSSTTEEM

M  IISS  B

BEEIIN

NG

G  IIN

NSSTTA

ALLLLEED

D  B

BYY  A

A  SSEEC

CU

UR

RIITTYY  IIN

NSSTTA

ALLLLEER

R  O

OR

R  EELLEEC

CTTR

RIIC

CA

ALL  EEN

NG

GIIN

NEEEER

R,,  P

PLLEEA

ASSEE  EEN

NSSU

UR

REE  TTH

HA

ATT  A

A

C

CO

OP

PYY  O

OFF  TTH

HEESSEE  IIN

NSSTTR

RU

UC

CTTIIO

ON

NSS  IISS  G

GIIV

VEEN

N  TTO

O  TTH

HEE  C

CU

USSTTO

OM

MEER

R  FFO

OR

R  R

REETTEEN

NTTIIO

ON

N  A

AN

ND

D  FFU

UTTU

UR

REE  R

REEFFEER

REEN

NC

CEE..

This  alarm system can provide valuable protection for your home and property if used properly. However, the system cannot

guarantee complete protection against burglary or robbery. Therefore, the manufacturer, distributor or supplier will not be

held responsible for any loss or damage which may occur.

6-ZONE EASYFIT INTRUDER ALARM

Check the contents of the
packaging:
• 1x6 zone control panel
• External siren 
• 9V PP3 alkaline back up

system battery

• Mains adaptor
• 4 PIR sensors
• 2 sets of hardwired door

contacts

• 8 sticky pads
• Fixing screws
• Cable clips
• Wall plugs
• Screwdriver (fits PIR cover

screws)

• 50m of multi-core alarm

cable

• Fixing bracket

IMPORTANT

In certain areas of the country you are required by law to
notify the Police and Local Authority when you install an
Alarm System. Since the requirements of each Authority
differ, we suggest that you contact the Environmental Officer
of your local Borough for full information about your local
area‘s by-laws.

Please note that this equipment and its components have NO user serviceable parts.

If you experience any difficulties call our Helpline.

M

MIIC

CR

RO

OM

MA

AR

RK

K  H

HEELLP

PLLIIN

NEE  TTEELL::  0

08

8770

0  2

24

411  3

30

02

29

9

Monday to Friday (8.30am to 5pm)

www.micromark.co.uk

C

CO

ON

NTTEEN

NTTS

S

Planning your system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Start with installing the control panel and siren  . . . . . . . . . . . .4
Fitting PIRs and door contacts  . . . . . . . . . . . . . . . . . . . . . . . . . .6
Wiring the control panel  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Control panel status  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Total immobilisation of system . . . . . . . . . . . . . . . . . . . . . . . . . .8
Checking the system – Walk test  . . . . . . . . . . . . . . . . . . . . . . . .8
Checking the system – Bell test mode . . . . . . . . . . . . . . . . . . . .8
System entry time  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
System exit time  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Bell reset  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
To change password  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
To arm the system  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
To disarm the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Panic alarm  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Chime zone  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Part Guard  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Back cover
Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Back cover

K

KIITT  C

CO

ON

NTTEEN

NTTS

S

P

Plle

ea

asse

e  n

no

otte

e::  B

Be

effo

orre

e  yyo

ou

u  sstta

arrtt  tto

o  iin

nsstta

allll  tth

hiiss  M

Miiccrro

om

ma

arrkk  A

Alla

arrm

m,,  w

we

e  a

ad

dvviisse

e  tth

ha

att  yyo

ou

u  ssh

ho

ou

ulld

d  tta

akke

e  a

ad

de

eq

qu

ua

atte

e  ssa

affe

ettyy  p

prre

ecca

au

uttiio

on

nss

w

wh

he

en

n  u

ussiin

ng

g  p

po

ow

we

err  tto

oo

ollss  a

an

nd

d  lla

ad

dd

de

errss..  P

Prro

otte

ecctt  yyo

ou

urr  e

eyye

ess  w

wh

he

en

n  d

drriilllliin

ng

g  a

an

nd

d  

n

ne

evve

err u

usse

e  a

ap

pp

plliia

an

ncce

ess  iin

n  d

da

am

mp

p  o

orr  w

we

ett  cco

on

nd

diittiio

on

nss..

PIR SENSORS

MAINS ADAPTOR

DOOR
CONTACTS

ALARM CABLE

FIXING BRACKET

CONTROL PANEL

SIREN

www.ukpanels.com

Summary of Contents for MM23207

Page 1: ...all an Alarm System Since the requirements of each Authority differ we suggest that you contact the Environmental Officer of your local Borough for full information about your local area s by laws Ple...

Page 2: ...above a heat source such as radiator or in conservatories or draughty areas When this system is armed keep pets out of areas protected by PIR sensors Position control panel near a power socket Now st...

Page 3: ...N EXISTING DOOR CONTACT TYPICAL WIRING DIAGRAM SHOWING PIR AND DOOR CONTACTS WITHIN ZONE 1 THE ENTRY EXIT ZONE BLACK WIRES TWISTED AND TAPED TOGETHER TRIM RED WIRES BACK TO INSULATION AND COVER WITH T...

Page 4: ...ing and pipework When planning the wiring avoid awkward cable runs to the control panel siren box PIRs and door contacts 1 Install the control panel out of reach of young children Mark for two vertica...

Page 5: ...y plugs 9 Bring the cable to the positon of the siren box and cut the cable allowing enough surplus for wiring into the siren terminal block Strip the wires and connect them to the teminal block as sh...

Page 6: ...ed cable through and connect the wires to the terminal block observing the colours Replace the cover and screw Use a sticky pad and secure the PIR to the mounting surface Run the cable back to the con...

Page 7: ...m cable see accessories and cut short the blue wire Anti tamper spring Tape down the anti tamper spring Figure 5 before connecting the back up battery otherwise as soon as the back up battery is conne...

Page 8: ...it t p pr ro og gr ra am mm mi in ng g P Pr re es ss s P P 6 6 E E All zones LEDs will flash with the control panel siren and the outside siren sounding for 15 seconds P Pr re es ss s P P 0 0 E E t to...

Page 9: ...to exit after arming the system with the password before the sirens sound The exit time is set by the factory to 15 seconds but this can be changed to a choice of 7 other exit times to suit you If for...

Page 10: ...s s P P 1 11 12 22 2 E E t to o e en nt te er r p pr ro og gr ra am mm mi in ng g Status LED flashes 3 1 E E SETTING UP CHECK LIST Have you done the walk test Have you done the bell test Have you set...

Page 11: ...re es ss s P P a an nd d E E together until alarm sounds status LED on E En nt te er r p pa as ss sw wo or rd d to stop alarm E En nt te er r p pa as ss sw wo or rd d again to reset system 1 2 Should...

Page 12: ...L La an ne e L Lo on nd do on n N N1 17 7 7 7R RQ Q Micromark continuously tries to improve its products for the benefit of its customers For this reason we reserve the right to make changes to any pr...

Reviews: