6
FITTING PIRs AND DOOR CONTACTS
Walk to the proposed position of the PIR sensor.
Allow enough cable to reach the control panel.
Unscrew the fixing screw at the base of the PIR and
remove the front cover. Remove the knockout at the
base of the back casing. Strip the wires to bare the
ends.
1
Fit the door contact with the screws
supplied, and leave a gap of 5mm
between the leading edges Fix the
wireable contact to the frame.
4
Follow the same procedure for each of
the zones. At the control panel m
ma
arrkk
tth
he
e w
wiirre
ess w
wiitth
h tth
he
e zzo
on
ne
ess ffrro
om
m w
wh
hiicch
h
tth
he
eyy a
arre
e ffrro
om
m..
6
Thread the stripped cable through and connect the
wires to the terminal block observing the colours.
Replace the cover and screw.
Use a sticky pad and secure the PIR to the mounting
surface. Run the cable back to the control panel
taking the shortest route and secure it with cable
clips. Repeat for the next PIR.
2
CHECK LIST
Are PIRs wired correctly?
Are the PIRs securely mounted?
Is the gap between door contacts correct?
Are the door contacts wired correctly?
Are the wires marked with their zones?
Run the wiring to the door contacts
(see wiring diagrams page 3). The
picture shows door contacts wired
directly to the control panel. Cut back
the red wire to the insulation and tape
the end. Repeat for next door contact.
5
PIRs
DOOR CONTACTS
AT THE CONTROL PANEL
3
If additional cable is
required, use 4-core
alarm cable (see
accessories) and cut
short the blue wire.
www.ukpanels.com