SYSTEM ENTRY TIME

Entry time is the period
of time allowed for you
to enter and disarm
the system with the
password (factory set
to 1122), before the
sirens sound. 
The entry time is set by
the factory to 20
seconds but this can
be changed to a
choice of 7 other entry
times to suit you. 

If for any reason the
sirens sound, p

prre

essss

11112

22

2  to disarm.

Then P

Prre

essss  P

P  2

2  EE  and within 5

seconds your choice.
((IIff  yyo

ou

u  d

do

o  n

no

ott  d

de

ecciid

de

e  w

wiitth

hiin

n  5

5

sse

ecco

on

nd

dss,,  tth

hrre

ee

e  ssh

ho

orrtt  b

blle

ee

ep

pss

w

wiillll  b

be

e  h

he

ea

arrd

d,,  a

an

nd

d  yyo

ou

u  w

wiillll

h

ha

avve

e  tto

o  e

en

ntte

err  P

P  2

2  EE  a

an

nd

d  sstta

arrtt

a

ag

ga

aiin

n..))

Then P

Prre

essss  P

P  0

0  EE  to exit

programming. 

1

2

3

4

P

Prre

essss  3

3  EE which is the

program for 40 seconds.
If entered correctly, a
continuous bleep will be
heard for 2 seconds. 

For example, to change the
entry time to 40 seconds (see
choices in Table): 
P

Prre

essss  P

P  11112

22

2  EE  tto

o  e

en

ntte

err

p

prro

og

grra

am

mm

miin

ng

g..

Example:

Exit time is the period
of time allowed for you
to exit after arming the
system with the
password, before the
sirens sound. 
The exit time is set by
the factory to 15
seconds but this can
be changed to a
choice of 7 other exit
times to suit you. 

If for any reason the
sirens sound, p

prre

essss

11112

22

2  to disarm.

SYSTEM EXIT TIME

1

For example, to change the
exit time to 60 seconds (see
choices in Table): 
P

Prre

essss  P

P  11112

22

2  EE  tto

o  e

en

ntte

err

p

prro

og

grra

am

mm

miin

ng

g..

Then P

Prre

essss  P

P  3

3  EE  and within 5

seconds your choice.
((IIff  yyo

ou

u  d

do

o  n

no

ott  d

de

ecciid

de

e  w

wiitth

hiin

n  5

5

sse

ecco

on

nd

dss,,  tth

hrre

ee

e  ssh

ho

orrtt  b

blle

ee

ep

pss

w

wiillll  b

be

e  h

he

ea

arrd

d,,  a

an

nd

d  yyo

ou

u  w

wiillll

h

ha

avve

e  tto

o  e

en

ntte

err  P

P  3

3  EE  a

ag

ga

aiin

n..))

2

3

P

Prre

essss  4

4  EE   which is the

program for 60 seconds.
If entered correctly, a
continuous bleep will be
heard for 2 seconds.

Then P

Prre

essss  P

P  0

0  EE  to exit

programming. 

4

Example:

Choices are:
11EE

10 seconds

0

0EE

15 seconds

2

2EE

20 seconds

3

3EE

40 seconds

4

4EE

60 seconds

5

5EE

90 seconds

6

6EE

120 seconds

77EE

240 seconds

To choose other exit times:
11EE

10 seconds

0

0EE

15 seconds

2

2EE

20 seconds

3

3EE

40 seconds

4

4EE

60 seconds

5

5EE

90 seconds

6

6EE

120 seconds

77EE

240 seconds

www.ukpanels.com

Summary of Contents for MM23207

Page 1: ...all an Alarm System Since the requirements of each Authority differ we suggest that you contact the Environmental Officer of your local Borough for full information about your local area s by laws Ple...

Page 2: ...above a heat source such as radiator or in conservatories or draughty areas When this system is armed keep pets out of areas protected by PIR sensors Position control panel near a power socket Now st...

Page 3: ...N EXISTING DOOR CONTACT TYPICAL WIRING DIAGRAM SHOWING PIR AND DOOR CONTACTS WITHIN ZONE 1 THE ENTRY EXIT ZONE BLACK WIRES TWISTED AND TAPED TOGETHER TRIM RED WIRES BACK TO INSULATION AND COVER WITH T...

Page 4: ...ing and pipework When planning the wiring avoid awkward cable runs to the control panel siren box PIRs and door contacts 1 Install the control panel out of reach of young children Mark for two vertica...

Page 5: ...y plugs 9 Bring the cable to the positon of the siren box and cut the cable allowing enough surplus for wiring into the siren terminal block Strip the wires and connect them to the teminal block as sh...

Page 6: ...ed cable through and connect the wires to the terminal block observing the colours Replace the cover and screw Use a sticky pad and secure the PIR to the mounting surface Run the cable back to the con...

Page 7: ...m cable see accessories and cut short the blue wire Anti tamper spring Tape down the anti tamper spring Figure 5 before connecting the back up battery otherwise as soon as the back up battery is conne...

Page 8: ...it t p pr ro og gr ra am mm mi in ng g P Pr re es ss s P P 6 6 E E All zones LEDs will flash with the control panel siren and the outside siren sounding for 15 seconds P Pr re es ss s P P 0 0 E E t to...

Page 9: ...to exit after arming the system with the password before the sirens sound The exit time is set by the factory to 15 seconds but this can be changed to a choice of 7 other exit times to suit you If for...

Page 10: ...s s P P 1 11 12 22 2 E E t to o e en nt te er r p pr ro og gr ra am mm mi in ng g Status LED flashes 3 1 E E SETTING UP CHECK LIST Have you done the walk test Have you done the bell test Have you set...

Page 11: ...re es ss s P P a an nd d E E together until alarm sounds status LED on E En nt te er r p pa as ss sw wo or rd d to stop alarm E En nt te er r p pa as ss sw wo or rd d again to reset system 1 2 Should...

Page 12: ...L La an ne e L Lo on nd do on n N N1 17 7 7 7R RQ Q Micromark continuously tries to improve its products for the benefit of its customers For this reason we reserve the right to make changes to any pr...

Reviews: