spaced during welding. The Setting Bar has flats cut into each end that properly position the end
brackets.
Figure 2
– os3610 Setting Bar
The Setting Bar is inserted in both mounting bracket and held in place with the set screws shown
in Figure 3.
Figure 3
– Close up of mounting bracket & Setting Bar
The steel surface should be cleaned to remove scale, rust, dirt, and oil. Position the Setting Bar
with the attached mounting brackets on the steel surface to be measured. Align the axis of the
Setting Bar with the axis of strain to be measured. While holding the mounting brackets firmly
against the surface, weld the edges shown in Figure 4 in the indicated sequence.