10
The actual flow rate should be checked holding the
HERBIDOME 350 in the spraying position (see 'TO
START SPRAYING'). Remove the feed nozzle from
the atomiser and allow the liquid to flow into a suitable
container .
The yellow feed nozzle is used only to direct the flow
into the atomiser disc.
Important note. The table below is based on water only.
Herbidome 350 flow restrictors
The details of the 3 restrictors are as below;
Important note.
The above table is based on a forward speed of 3 kph and the formula used is;
Nozzle flow rate (L/min) = (Application rate (L/ha treated) x Walking speed (kph)
x Sprayed width (metres)) divided by 600
You will note from the attached pictures the restrictors are supplied as part of the
outlet side hose connector of the in-line liquid feed on/off tap.
Number of Rings
Size
1 Ring
0.65 mm
44 mls/min
25.14 L/ha
2 Rings
1.00 mm
68 mls/min
38.86 L/ha
3 Rings
1.15 mm
108 mls/min
61.71 L/ha
Flow Rates (approximate)
Item
8401
8402
8403
Summary of Contents for Herbidome 350