PlatinumRAID Owner’s Manual
5-RAID Controls-LCD/Terminal
6.3 Show System Events
To view the RAID subsystem events, select the
“Show System Events”
option and press
ENT
.
The system events logged will be displayed. System events are logged chronologically, and
may be scrolled through.
6.4 Clear all Event Buffers
To clear all events in the system log, scroll to select the
“Clear all Event Buffers”
option and
press
ENT
. The confirmation message will be displayed and press the
ENT
to clear all event
buffers or
ESC
to abort the action.
6.5. Hardware Information
To view the RAID subsystem controller’s hardware monitor information, Scroll to select the
“Hardware Information”
option and press
ENT
. All hardware information will be displayed.
Scroll to browse all the hardware information. The Hardware Monitor Information provides
the temperature, fan speed (chassis fan) and voltage of the internal RAID subsystem. The
temperature items list the current states of the controller board and backplane.
The Platinum RAID has an audiovisual alert system to inform the user of environmental
failure. The warning messages will indicate through the LCD, LED and alarm buzzer. The
following is a table of monitoring threshhold values:
Monitored Item
Warning Condition
Controller Board Temperature
> 60° Celsius
Backplane Temperature
> 55° Celsius
Controller Fan Speed
< 1900 RPM
Power 12V
< 10.5V or > 13.5V
Power 5V
< 4.7V or > 5.3V
Power 3.3V
< 3.0V or > 3.6V
CPU Core V1.5V
< 1.35V or > 1.65V
6.6 System Information
Choose this option to display Main processor, CPU Instruction cache/ and data cache size,
firmware version, serial number, controller model name, and the cache memory size. To check
the system information, press
ENT
to enter the main menu. Scroll to select the Show System
Information option, and then press
ENT
. All major controller system information will be
displayed. Scroll to browse all the system information.