<phone-number>: phone number
Possible value:
<#>: 1 to 6
Example:
SP1659P(alarm-sms)# set server 192.168.1.7
SP1659P(alarm-sms)# set user ruby
Password:
Confirm Password:
SP1659P(alarm-sms)# set phone-number 1 0968777777
show
Syntax
: show
Description
: The Show here is to display the configuration of SMS trap event.
Argument
: None.
Possible value:
None.
Example:
SP1659P(alarm-sms)# show
SMS Server : 192.168.1.7
Username :
Password : ****************
Mobile Phone 1: 0968777777
Mobile Phone 2:
Mobile Phone 3:
Mobile Phone 4:
Mobile Phone 5:
Mobile Phone 6:
4.3.4 autologout
autologout
Syntax
: autologout <time>
Description
: To set up the timer of autologout.
Argument
: <time>: range 1 to 3600 seconds, 0 for autologout off, current setting is 180 seconds.
Possible value:
<time>: 0, 1-3600
Example:
SP1659P# autologout 3600
Set autologout time to 3600 seconds
4.3.5 bandwidth
set egress-rate
Syntax
: set egress-rate <range> <data_rate>
Description
: To setup the egress-rate of the port.
Argument
:
<range>:syntax 1,5-7, available from 1 to 26
<data_rate>: 66-1024000(Kb). #1-24: 66-102400(Kb, # 25-26: 66-1024000(Kb)
Possible value:
<range>: 1 to 26
<data_rate>: #1-24: 66-102400(Kb), # 25-26: 66-1024000(Kb)
78