Example:
SP1659P(dhcp-boot)# show
Dhcp Boot : Enable
Second : 10
4.3.8 diag
diag
Syntax:
diag
Description:
Diag is used to test whether UART, DRAM, Flash and EEPROM is normal or not.
Argument:
None.
Possible value:
None.
Example:
SP1659P(diag)# diag
EEPROM Test : OK
UART Test : OK
DRAM Test : OK
Flash Test : OK
loopback
Syntax:
Loopback
Description:
For Internal/External Loopback Test.
Argument:
None.
Possible value:
None.
Example:
SP1659P(diag)# loopback
Internal Loopback Test : OK
External Loopback Test : Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Fail
ping
Syntax:
ping <ip>
Description:
To confirm that whether the remote end-station or switch itself is alive or not.
Argument:
[ip] : ip address or domain name
Possible value:
IP address, e.g. 192.168.2.65 or domain name, e.g. tw.yahoo.com
Example:
SP1659P(diag)# ping 192.168.1.115
Gateway : 192.168.1.253
192.168.1.115 is alive.
4.3.9 firmware
set upgrade-path
Syntax
: set upgrade-path <filepath>
Description
: To set up the image fie that will be upgraded.
Argument
: <filepath>: upgrade file path
Possible value:
<filepath>: upgrade file path
Example:
SP1659P(firmware)# set upgrade-path sp1659P_v0.92.bin.gz
82