Installation 

As with any electric device, you should place the equipment where it will not be subjected to 

extreme temperatures, humidity, or electromagnetic interference. Specifically, the site you 

select should meet the following requirements: 

 

The ambient temperature should be between 0 to 50 degrees Celsius. 

 

The relative humidity should be less than 90 percent, non condensing. 

 Surrounding 

electrical 

devices should not exceed the electromagnetic field (RFC) 

standards for IEC 801 3, Level 2 (3V/M) field strength. 

 

Make sure that the equipment receives adequate ventilation. Do not block the 

ventilation holes on each side of the switch or the fan exhaust port on the side or 

rear of the equipment. 

 

Mounted to 19-inch standard rack 

1. 

Wear a grounding device for electrostatic discharge. 

2. 

Install screws through mounting ears into each side. 

3. 

Locate Converter Chassis at 19-inch mounting rails and screw up the front 

brackets. 

 

 

Desktop or any flat surface 

1. 

Simply put the chassis on the desired place. 

2. 

Ensure the chassis receives good ventilation. 

 

The side-in Media Converter and Converter Chassis should be supplied only from 

the same source; both Media Converter and Chassis are built to match each other at 

dimensions, DC power jack, DC receptacle and power safety. 

 

Verify the Media Converter is right for this Chassis and 5VDC power jack on 

converter back, and carefully slide in and plug to match 19” rack slot +5VDC 

receptacle. 

 

Before connection with the power cord, please set the Power Switch at “OFF” 

position. 

 

Two power supplies, 12 converter modules and two 8cm DC fans are providing hot 

swappable. 

 

 

 

 

3

 

Summary of Contents for SP382A

Page 1: ...Quick Installation Guide Media Converter Chassis Model No SP382A World Wide Web www micronet com tw www micronet info ...

Page 2: ...best solution for users to manage media converters Since the converter is mounted directly on the chassis no power cable or wire is required Moreover a redundant power is offered cope with any accidental breakdown of power supply Package Content Thank you for purchasing Micronet Media Converter Chassis Before you start installing the Media Converter Chassis verify the following items in the packag...

Page 3: ... to 19 inch standard rack 1 Wear a grounding device for electrostatic discharge 2 Install screws through mounting ears into each side 3 Locate Converter Chassis at 19 inch mounting rails and screw up the front brackets Desktop or any flat surface 1 Simply put the chassis on the desired place 2 Ensure the chassis receives good ventilation The side in Media Converter and Converter Chassis should be ...

Page 4: ...d share the current load In case that one of them should fail the other will instantaneously take 100 of the load without any loss Similarly if one power supply is removed from servicing it can be switched off and removed while the chassis continues functioning The chassis system can hold two power supplies and up to twelve media converters and therefore it is necessary to provide a good cooling s...

Page 5: ...Indication Please refer to the following table for LED indication of SP382A LED Status Indication Power A Green Power Module A 5VDC is on Power B Green Power Module B 5VDC is on Green Two 8cm Fans are working well Flashing One of both side Fans is malfunctioning lower rotation Fan Off Any 8cm DC Fans is bad 5 ...

Page 6: ...SP342C 343C SP373F SP373G series 6 SP362C SP363C series Per slot DC Power Output 5VDC 1A Per slot DC Power Plug 2 5mm DC receptacle Power Input 100 240VAC 50 60Hz 48VDC Power Dissipation 60W maximum Operating Temperature 0 50 C Storage Temperature 10 70 C Operating Humidity 50 70 Dimension 89 X 440 X 258 6mm H x W x D Weight 5 8kg Emission FCC part 15 Class A CE ...

Page 7: ...CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures 7 ...

Reviews: