Chapter 1
Setup and Installation
1-6
MS-5000 Multidrop Concentrator User’s Manual
1–Set
up an
d I
nst.
Power Connector
The power connector uses a 5-pin DIN receptacle with the following pin
assignments:
If you are supplying the required DC voltages, a mating power connector
is required.
Caution:
Switching power supplies for Microscan equipment with a
switching noise of 75 mV or greater with +5 VDC, or of 30 mV or greater
with ±12 VDC is not recommended due to excessive ripple characteris-
tics.
Power Connector Pin Assignments.
Table 1-2
Pin Connection
1
DC Ground
2
Chassis Ground
3
+5 VDC .35A
4
-12 VDC .30A
5
+12 VDC .30A
2
1
4
5
3
Figure 1-5 Power Connector