Chapter 5
Profile Card Configuration
5-8
MS-5000 Multidrop Concentrator User’s Manual
5–
P
ro
fi
le
C
a
rd
Mode 9:
Host Port Turnaround Timeout
Mode 10:
Host Port Intercharacter Timeout
Mode 11:
LAN Port Turnaround Timeout
Mode 9, 10, and 11 will accept binary values from 1 to 250.
To set these modes, multiply the desired number of seconds for timeout by
10 and enter the result in binary format.
See mode 1 switch settings for timeout ranges from 0.1 seconds to 5 sec-
onds. (Although not shown for mode 1, switches 7 and 8 are OFF for 1
through 50.)
See “Binary Calculations” on page 5-9 for timeout ranges from 5.1 seconds
to 25 seconds.
Mode 12:
Blocking Factor
1
Mode 12 will accept binary values from 1 to 127. Values are set the same
as mode 9, 10 and 11.
See mode 1 for switch settings.
1. See also, “<C>Send Partial Buffer to Host Command” on page 4-13 for related infor-
mation.
Mode Switches
= On
= Off
Mode Switches
= On
= Off
Mode Switches
= On
= Off
Mode Switches
= On
= Off