Serial Commands
MS-5000 Multidrop Concentrator User’s Manual
4-9
4–Oper
a
ti
ons.
new address (^Y) must be assigned in the User Defined command
<KF7,^Y>.
Preamble
Prepend up to five ASCII characters to decoded data.
Format: 51<
Kd
first data field,second data field
>CR
Example:
To enable Preamble and send an FF (form feed) character, enter
51<Kd1,^L>CR
.
Postamble
Append up to two ASCII characters to decoded data.
Format: 51<
Ke
first data field,second data field
>CR
Example:
To enable Postamble and send an FF (form feed) character,
enter
51<Ke1,^L>CR
.
LRC
The exclusive OR of all characters following SOM (start of message) up to
and including the EOM (end of message).
Format: 51<
Kc
status
>CR
Example:
To enable LRC, enter
51<Kc1,^L>CR
.
RTS/CTS
Ready to Send and Clear to Send
Format: 51<
Kj
status
>CR
Example:
To enable RTS/CTS, enter
51<Kj1>CR
.
First Data Field:
0 = Disable
1 = Enable
Second Data Field:
Send up to five ASCII characters
except a null (00H).
First Data Field:
0 = Disable
1 = Enable
Second Data Field:
Send up to five ASCII characters
except a null (00H).
0 = Disable
1 = Enable
0 = Disable
1 = Enable
Summary of Contents for MS-5000
Page 1: ...MS 5000 Multidrop Concentrator User s Manual P N 83 005000 REV J...
Page 8: ...viii MS 5000 Multidrop Concentrator User s Manual...
Page 52: ...Chapter 3 Menu Configuration 3 18 MS 5000 Multidrop Concentrator User s Manual 3 Serial Config...
Page 66: ...Chapter 4 Serial Commands 4 14 MS 5000 Multidrop Concentrator User s Manual 4 Operations...
Page 90: ...A 14 MS 5000 Multidrop Concentrator User s Manual Appendices...