Quadrus Verifier User’s Manual
1-11
Quick Start
Step 10 — Verify Symbol
When you have finished setting and saving verification parameters and output preferences,
move to the
Report
tab and click the button that corresponds to the type of verification
routine you need to perform.
• For ISO/IEC 15415 Verification, click
ISO/IEC 15415...
and then select
Single Capture
or
Multi-Capture
when the
ISO 15415 Single or Multi-Capture
dialog appears.
• For AS9132 Verification, click
AS9132A Verification
.
• For AIM DPM Verification, click
AIM DPM Quality Guideline
.
Verification results are displayed in the viewing area at the lower right of the
Verification
view.
Save Report
is explained in greater detail in Step
Generate and Save Verification Report
.
Select the desired capture process for ISO/IEC
15415 verification.
Summary of Contents for Quadrus Verifier
Page 1: ...Quadrus Verifier User s Manual P N 83 006702 Rev C ...
Page 30: ...1 18 Quadrus Verifier User s Manual Generate and Save Verification Report ...
Page 150: ...4 10 Quadrus Verifier User s Manual UII Parsing ...
Page 152: ...Quadrus Verifier User s Manual ...
Page 178: ...5 26 Quadrus Verifier User s Manual Aux Port System Data Status ...
Page 210: ...6 32 Quadrus Verifier User s Manual Setting Up the Verifier for EZ Trax ...
Page 302: ...8 62 Quadrus Verifier User s Manual Configuring EZ Trax Output ...
Page 318: ...9 16 Quadrus Verifier User s Manual New Master Pin ...
Page 326: ...10 8 Quadrus Verifier User s Manual Service Message ...
Page 362: ...12 14 Quadrus Verifier User s Manual Request All Database Settings ...
Page 390: ...14 22 Quadrus Verifier User s Manual Status Requests ...
Page 404: ...15 14 Quadrus Verifier User s Manual Ordered Output Filter ...
Page 444: ...A 30 Quadrus Verifier User s Manual Glossary of Terms ...