Quadrus Verifier User’s Manual
8-3
I/O Parameters
I/O Parameters Serial Commands
Note:
The Quadrus Verifier does not have an
Output 3
option by default. If your application
requires an Output 3, contact your Microscan sales representative for more information.
Symbol Data Output
<
K705,
symbol data output status,when to output
>
No Read Message
<
K714,
no read message status,no read message
>
Bad Symbol Message
<
K715,
[unused],message
>
No Symbol Message
<
K716,
[unused],message
>
1D/Stacked Symbology
Qualification
<
K717,
minimum number of bars,minimum number of qualified scans,start/
stop status
>
2D Symbology
Qualification
<
K718,
finder pattern status,symbol size mode,symbol size 1,symbol size
2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension
tolerance,orientation mode,orientation value
>
Read Duration Output
<
K706,
status,separator
>
LED Indicators
<
K750,
green flash mode,target pattern status,green flash duration
>
Beeper
<
K702,
beeper status
>
LED Configuration
<
K737,
LED mode,ISO/IEC 15415 grade,DPM grade
>
Serial Verification
<
K701,
serial command echo status,serial command beep status,control/hex
output
>
Video Output
<
K760,
video output status,trigger image mode,image frame
>
Image Output
<
K739,
image output status,com port,file format,JPEG quality
>
EZ Trax Output
<
K757,
comm port,image mode,image format,jpeg quality,object info output
>
Image Captioning
<
K762,
mode
>
Synchronous Trigger
<
K761,
synchronous trigger mode
>
EZ Button
<
K770,
global status,default on power-on,load IP database,save for power-on
>
EZ Button Modes
<
K771,
position 1 mode,position 2 mode,position 3 mode,position 4 mode
>
Input 1
<
K730,
input mode,active state
>
Output 1 Parameters
<
K810,
output on,active state,pulse width,output mode
>
Trend Analysis Output 1
<
K780,
trend analysis mode,number of triggers,number to output on
>
Diagnostic Warnings Output 1
<
K790,
over temp,service unit,external camera disconnect
>
ISO/IEC 15415 Verification
Output 1
<
K830,
grade,decode,symbol contrast,fixed pattern damage,axial non-unifor-
mity,grid non-uniformity,modulation,unused error correction,print growth value
>
AS9132 Verification Output 1
<
K840,
dot center offset,cell fill, dot ovality,angle of distortion,symbol contrast,
quiet zone
>
Output 2 Parameters
<
K811,
output on,active state,pulse width,output mode
>
Trend Analysis Output 2
<
K781,
trend analysis mode,trigger evaluation period,number to output on
>
Diagnostic Warnings Output 2
<
K791,
over temp,service unit,external camera disconnect
>
ISO/IEC 15415 Verification
Output 2
<
K831,
grade,decode,symbol contrast,fixed pattern damage,axial non-unifor-
mity,grid non-uniformity,modulation,unused error correction,print growth value
>
AS9132 Verification Output 2
<
K841,
dot center offset,cell fill, dot ovality,angle of distortion,symbol contrast,
quiet zone
>
Summary of Contents for Quadrus Verifier
Page 1: ...Quadrus Verifier User s Manual P N 83 006702 Rev C ...
Page 30: ...1 18 Quadrus Verifier User s Manual Generate and Save Verification Report ...
Page 150: ...4 10 Quadrus Verifier User s Manual UII Parsing ...
Page 152: ...Quadrus Verifier User s Manual ...
Page 178: ...5 26 Quadrus Verifier User s Manual Aux Port System Data Status ...
Page 210: ...6 32 Quadrus Verifier User s Manual Setting Up the Verifier for EZ Trax ...
Page 302: ...8 62 Quadrus Verifier User s Manual Configuring EZ Trax Output ...
Page 318: ...9 16 Quadrus Verifier User s Manual New Master Pin ...
Page 326: ...10 8 Quadrus Verifier User s Manual Service Message ...