  Alarm contact (Relay Contact) 

 
The alarm contact allows the connection of any external alarm system in order to 
monitor the operation status. The contact is a 3-ping plug connector at the front of the 
switch module. There are both pins, normally open (NO) and normally closed (NC) 
available. 
 
The contact is switched in case of a power loss. If the switch is confidured into ring 
mode the contact is also switched if the fiber ring is broken in one segment. 
Geschaltet wird bei Ausfall der Hauptstromversorgungsspannung. Ist der Switch für 
den Ringbetrieb konfiguriert, so wird zusätzlich die Unterbrechung der Glasfaser-
Verbindung signalisiert. 
 
ATTENTION: The maximum power level for this contact is 0.5 A at 60 V DC. It is NOT 
allowed to connect devoces with 230 V AC power there. 
 

  Transmission Speed 

 
The  Twistes  Pair  ports  of  the  switches are selecting automatically the highest possible 
speed by using autonegotiation. The LEDs are indicating the selected mode. 
 
The LEDs are showing the following information. 
 
LED 

Function 

Port 1...8 

Link- (on) and activity (blinking) for each copper port 

Port 9..10  Link- (on) und activity (blinking) fort he two SFP slots 

Ring 

Switch configured into ring mode 

RM 

Ring-Master (only if ring mode is activated) 

Alarm 

Alarm contact released 

 
 

  Twisted Pair Coinnections 

 
The integrated auto-crossing function of all Twisted-Pair ports makes the use of crossed 
patch cables unnecessary. The switch automatically detects the pinout of the connected 
cable and adapts the port accordingly. For all connections standard 1:1 Twisted Pair 
cables can be used. 
The Autonegotiation mechanism detects automatically the speed and transmission 
mode (full or half duplex) between connected ports. A manual configuration is not 
required but possible via the integrated management. 

Summary of Contents for MS415259M

Page 1: ...SFPs the MICROSENS industrial switches also offer seven 10 100Base TX connections for linking such Ethernet terminals as machine controls network uplinks consoles and other network participants and one 10 100 1000Base T port for a central uplink connection This switch module for the MICROSENS 19 Access Platform offers the central concentration of the industrial fiber optic ring products Features G...

Page 2: ...ata rate 10 100 and 1000 Mbps LED displays Power ready for operation Lnk Act Link status Data traffic each Port Ring Switch is configured into ring mode RM Switch is ring master Alarm Fiber uplink interrupted ring failure or power supply failure Power Supply Standard 18 36 V DC via backplane Optional 36 72 V DC via backplane for PoE Option Fuse 1 A slow internal Power consumption 8 Watt typ Dimens...

Page 3: ...er modules of the same series freely The current supply is made from a central power supply via backplane Together with the power supply MS416004 and or MS416004M manageable version maximally 12 modules can be installed into 3HU chassis MS416001M or up to 20 into 4HU chassis front and back MS416010M Optionally a second power supply MS416004M for redundancy can be installed In this case 10 modules ...

Page 4: ... at 60 V DC It is NOT allowed to connect devoces with 230 V AC power there Transmission Speed The Twistes Pair ports of the switches are selecting automatically the highest possible speed by using autonegotiation The LEDs are indicating the selected mode The LEDs are showing the following information LED Function Port 1 8 Link on and activity blinking for each copper port Port 9 10 Link on und act...

Page 5: ... tool it is also possible to do the initial TCP IP setting IP address Gateway etc This configuration can be changed afterwards using the TCP IP protocol Attention The description for the initial settings can be found in the online manual The management information are available inside of the network inband management A special connection is not necessary Due to this all four twisted pair ports are...

Page 6: ...he ring stays at this location Normal operation status Data transmission in failure status Ring Mechanism The from MICROSENS patented protection mechanism supports the fast reconfiguration of the data transmission in case of failure of one fiber segment This function is a fixed feature of the industrial switch During this operation one switch is having the manager function all other switches are n...

Page 7: ...ne device fails this information is forwarded to the ring manager master by a special protocol The ring manager keeps the operation of the complete segment up Advantage of this solution is that the ring manager itself has not to be redundant because if the manager fails the data can not be multiplied The segments stays under operation To avoid that the signaling in case of failure has no affect on...

Page 8: ...nstallations must be carried out in accordance with local regulations Order Information Art No Description Connectors MS415259M 10 Port Switch Module 1x10 100 1000T or 1000BaseX auto detect 7x10 100TX Ring Redundancy 2x SFP Ports manageable SNMP web CLI VLANs QoS 8x RJ 45 2x SFP Slot 1x Alarm Contact Accessories Art No Description Connectors MS100193 SFP Fast Ethernet 1310 nm Multimode Transceiver...

Reviews: