At the menu point Hardware Setting it is possible to select the two modes master or 
slave. The switch which is configured in master mode is doing the ring manager 
functions to avoid the multiplication of the data.

 

 
If one connection or one device fails this information is forwarded to the ring manager 
(master) by a special protocol. The ring manager keeps the operation of the complete 
segment up. 
 
Advantage of this solution is that the ring manager itself has not to be redundant, 
because if the manager fails the data can not be multiplied. The segments stays under 
operation. 
 
To avoid that the signaling in case of failure has no affect on other rings, it is possible 
to define different rings with numbers from 0 to 255 by the network management. 
 
All switches with ring functionality are having the management features included and 
are offering the detection and signaling of any failure. 
 
With this concept a limitation in regards to the maximum ring length is not given. 
 
 
 

  Safety Notes 

 

WARNING:

 Infrared radiation as used for data transmission within the fiber optic, although 

invisible to the human eye, can nevertheless cause damage. 
 
To avoid damage to the eyes: 

 

never look straight into the output of fiber optic components – danger of blinding! 

 

cover all unused optical connections with caps. 

 

commission the transmission link only after completing all connections. 

 
The active laser components used with this product comply with the provisions of 

Laser Class 

1

 

DANGER:

 Conductive components of power and telecommunications networks can carry 

dangerously high voltage. 

To avoid electric shock:  

 

Do not carry out installation or maintenance work during lightning storms. 

 

All electric installations must be carried out in accordance with local regulations. 

Summary of Contents for MS650850M

Page 1: ... industrial switches also offer seven 10 100Base TX connections for linking such Ethernet terminals as machine controls network uplinks consoles and other network participants and one 10 100 1000Base T port for a central uplink connection In an extended version this switch is available with a third optical fiber port 1000Base X This port can be used alternative to the 10 100 1000Base T port For pa...

Page 2: ...y flashing of the fiber ports P1 Green Main Power Supply active Orange Main Power Supply missing P2 Green Backup Power Supply active Orange Backup Power Supply missing Ring Switch configured for ring mode RM Ring Master only in ring mode Alarm Fiber link interrupted or Power Supply problem Mounting 35 mm hat rail according DIN EN 50 022 Power supply 18 36 V DC optional 48 V DC max 500 mA by extern...

Page 3: ... speed and transmission mode full or half duplex between connected ports A manual configuration is not required Power supply The power supply is done by an external power supply with an output voltage of 24 V DC This power supply is not included at delivery but can be ordered separately MS700405 The connection is done by the pluggable screw terminals on the top of the device The connection of a re...

Page 4: ... protection against failures at minimum cabling expense In normal operation the ring connection is logically interrupted by monitoring device switch configured for Ring Master mode In case of failure broken connection or switch damage the logically interrupted connection is activated by Ring Master A big advantage of this solution is that no additional central device is necessary for the redundanc...

Page 5: ...g this operation one switch is having the manager function all other switches are normal ring switches Each switch is monitoring the status of the connected fiber segment In case of failure the connected switch forwards this information to the ring manager The ring manager terminates the interruption of the ring immediately The data is transmitted in all directions then This fast signaling a fast ...

Page 6: ...ngs with numbers from 0 to 255 by the network management All switches with ring functionality are having the management features included and are offering the detection and signaling of any failure With this concept a limitation in regards to the maximum ring length is not given Safety Notes WARNING Infrared radiation as used for data transmission within the fiber optic although invisible to the h...

Page 7: ...ing function 1x 10 100 1000Base T 7x 10 100Base TX 2x 1000Base SX SC multimode 850 nm 4x SC 8x RJ 45 2x Power 1x Alarm MS650852M Gigabit Ethernet Switch with ring function 1x 10 100 1000Base T 7x 10 100Base TX 2x 1000Base LX SC single mode 1310nm 10 km 4x SC 8x RJ 45 2x Power 1x Alarm MS650861M Gigabit Ethernet Switch with ring function 1x 10 100 1000Base T 7x 10 100Base TX 3x 1000Base SX SC multi...

Page 8: ...t 2 pin MS700421 Hat rail power supply 60 Watt 24 V 2 5 A wide range input 85 264 VAC In 3 pin Out 5 pin MS700422 Hat rail power supply 120 Watt 24 V 5 A wide range input 85 264 VAC In 3 pin Out 5 pin MS700430 Hat rail power supply 60 Watt 48 V 1 25 A wide range input 85 264 VAC In 3 pin Out 5 pin MS700434 DC DC hat rail power supply 24 Watt 24 V 1 0 A wide range input 18 75 V DC In 3 pin Out 2 pi...

Reviews: