Chapter 10 XML interface
high_level1 - high_level4
Configuration of the "low" and "high" level (only for channels in "Digital", "Cnt.Day" or
"Cnt.Intervl." mode)
Value
Explanation
0
The levels are set automatically.
Warmup time not equal to 0:
l
"high": >7V
l
"low": <6,3V
Warmup time equal to 0:
l
"high": >1,8V
l
"low": <1,62V
> 0mV
Level from which the signal at the universal input is interpreted as "high". "low"
is detected at the "high level" -10%.
Day changing time
Reset time of the day counter
Value
Explanation
0
00:00
60
01:00
120
02:00
:
:
:
:
1320
22:00
1380
23:00
pos_cycle
Position update interval
warmup
specifies the time for which the sensor supply is switched on before the measurement
measure_quick_factor
record interval = record interval / factor (from triggering)
alarm_record_alarmlo
1)
The "Warning" is recorded in the alarm list (read only).
alarm_record_alarmhi
1)
The "Alarm" is recorded in the alarm list (read only).
alarm_record_faultlo
1)
The "Fault warning" is recorded in the alarm list.
Rev. 01
87