Chapter 9 User interfaces
9.2.1.3.2 Config
Universal inputs
(digital modes)
Off
---
---
Digital
High level Configuration of the "low" and "high" level
0
The levels are set automatically.
Warmup time not equal to 0:
l
"high": >7V
l
"low": <6,3V
Warmup time equal to 0:
l
"high": >1,8V
l
"low": <1,62V
> 0mV
Level from which the signal at the
universal input is interpreted as "high".
"low" is detected at the "high level" -10%.
Cnt.Day
1)
High level Configuration of the "low" and "high" level
0
The levels are set automatically.
(see "Digital" mode)
> 0mV
Level from which the signal at the
universal input is interpreted as "high".
"low" is detected at the "high level" -10%.
Cnt.Intervl.
1)
High level Configuration of the "low" and "high" level
0
The levels are set automatically.
(see "Digital" mode)
> 0mV
Level from which the signal at the
universal input is interpreted as "high".
"low" is detected at the "high level" -10%.
1)
These modes are only available for universal input 1.
Rev. 01
61