Universal inputs
1)
4 x analogue or digital
Modes:
l
0/4...20mA: Resolution 6,3µA, max. 23,96mA, load 96Ω
l
0...2V: Resolution 610µV, max. 2,5V, load 10k086
l
0...10V: Resolution 7,97mV, max. 32V, load 4k7
l
PWM: 1...99%, max. 100Hz, min. pulse length 1ms, load 10k086
l
Frequency: 1...1000Hz, 10k086
l
Digital: max. 32V, low <0,99V, high >2,31V, load 10k086
l
Counter: min. pulse length 1ms, load 10k086
Additional information is provided in "Technical details about the universal inputs" on
page 65.
System time
Hardware real-time clock with its own buffer battery and automatic time
synchronisation with the server.
Additional information is provided in "Technical details about the system time" on page
75.
Internal sensors
Internal housing temperature
l
Measurement range: -20...+60°C
l
Resolution: 0,1°C
Humidity in the housing
l
Measurement range: 0...100% rH
l
Resolution: 0,1% rH
External
temperature sensor
2)
1 x PT100/1000 (including auto detection)
Additional information is provided in "Technical details about the PT100/1000
interface" on page 66.
Serial interface
1 x RS232 (4-wire)
3)
l
Baud rate: 600-115200
l
Stop bits: 1, 2
l
Parity: N, E, O
l
Data bits: 7, 8
l
Flow control: Off, RTS/CTS
1 x RS485 (2-wire)
4) 5)
l
Baud rate: 600-115200
l
Stop bits: 1, 2
l
Parity: N, E, O
l
Data bits: 7, 8
l
Load resistance: Off, 120Ω
Additional information is provided in "Technical details about the RS485 interface" on
page 66 and "Technical details about the RS232 interface" on page 67.
16
Rev. 05
Summary of Contents for myDatalogEASY V3
Page 2: ......
Page 13: ...Chapter 2 Declaration of conformity Chapter 2 Declaration of conformity Rev 05 13 ...
Page 14: ......
Page 42: ......
Page 76: ......
Page 88: ......
Page 102: ......
Page 110: ......
Page 116: ......
Page 234: ......
Page 244: ......
Page 252: ......
Page 254: ......
Page 266: ......
Page 276: ......