Chapter 3 Technical data
Outputs
2 x switchable 3,3V supply (max. 180mA )
1 x switchable and adjustable sensor supply:
The device logic can be used to vary the output voltage in the range of 5...24V .
l
5V
nominal
: 4,75V at I
out
= 50mA
l
12V
nominal
: 11,7V at I
out
= 50mA
l
15V
nominal
: 14,7V at I
out
= 50mA
l
24V
nominal
: 23,4V at I
out
= 50mA
1 x isolated switch contact:
l
I
max
: 130mA
l
U
max
: 32V
l
R
on
: 35Ω
l
f
max
: 1000Hz
Modes:
l
Digital
l
Frequency: Adjustment range 1...1000Hz, pulse duty factor 1...100%
l
PWM: Adjustment range 0...100%, frequency 0...1000Hz
l
Pulse: Pulse duration 1...500ms , pulse pause 1...500ms
l
Pulse/min
Additional information is provided in "Technical details about the outputs" on page 69.
Bluetooth
6)
5.0 compatible low energy module
USB interface
1 x mini-B USB 2.0 slave for the connection to a PC. The DeviceConfig configuration
program must be installed on the PC or the web-based development environment
rapidM2M Studio must be used to enable communication with the
myDatalogEASY V3 .
Additional information is provided in "Technical details about the USB interface" on
page 68.
Data memory
3MB internal flash memory.
The size of the data records is variable (max. 1024 Byte ) and is determined by the
Device Logic created by the user. The system-related overhead is 11 Byte per data
record.
Additional information is provided in"Functionality of the internal data memory" on
page 31.
Configuration
memory
10 independent blocks each with 4000 Byte
Rev. 05
17
Summary of Contents for myDatalogEASY V3
Page 2: ......
Page 13: ...Chapter 2 Declaration of conformity Chapter 2 Declaration of conformity Rev 05 13 ...
Page 14: ......
Page 42: ......
Page 76: ......
Page 88: ......
Page 102: ......
Page 110: ......
Page 116: ......
Page 234: ......
Page 244: ......
Page 252: ......
Page 254: ......
Page 266: ......
Page 276: ......