14.1.1 Division of a structured measurement data channel into individual data
fields
#histdata0 Measurements up
BatVoltage s16 title="Battery Voltage" decpl=2 units="V" vscale=0.001
InputVoltage s16 title="USB Voltage" decpl=2 units="V" vscale=0.001
The first line in the example above specifies the container to be used for the measurement data:
#histdata0:
The measurement data should be stored in histdata channel 0.
Measurements:
"Measurements" should be used as the name for the histdata channel.
up:
The data is only transmitted from the device to the server.
Note:
After specifying the direction of transmission other attributes (e.g. "title") could be added.
The second line in the example above describes the first measurement value in the measurement data
container used:
BatVoltage:
"BatVoltage" should be used as the name for the measurement value.
s16:
The data type used for the measurement value should be a 16-bit signed integer.
title:
Name of the measurement value that is displayed on the server
decpl:
Number of decimal places that should be displayed
units:
Unit of the measurement value that is displayed on the server
vscale:
Virtual scaling of the value (see "Attributes of the field definition" on page 238)
Note:
Name and data type must always be specified. Attributes are optional. Further attributes can
also be added.
The third line in the example above describes the second measurement value in the measurement data
container used.
236
Rev. 05
Summary of Contents for myDatalogEASY V3
Page 2: ......
Page 13: ...Chapter 2 Declaration of conformity Chapter 2 Declaration of conformity Rev 05 13 ...
Page 14: ......
Page 42: ......
Page 76: ......
Page 88: ......
Page 102: ......
Page 110: ......
Page 116: ......
Page 234: ......
Page 244: ......
Page 252: ......
Page 254: ......
Page 266: ......
Page 276: ......