11. Close the housing cover. The best option is to tighten the four screws crosswise (torque 0,5Nm; At the
first screw 0,7Nm because the threads have to be shaped into the base part first.) so that the housing
cover is positioned evenly.
Important note:
Ensure that the seals are clean and intact before closing the housing cover.
Remove any impurities and/or dirt. The manufacturer shall not be liable for any damage to the
device caused by leaky or faulty seals.
Closing the housing cover
1
myDatalogEASY V3 base unit
3
Housing cover
2
Delta PT M3.5x25 Torx 15
12. Check that the housing cover is positioned correctly on all sides and that no foreign materials have
been trapped between the housing and housing cover.
Important note:
The manufacturer is not liable for any damage that is caused by housing
covers that are not closed correctly.
The following step is only necessary if you are using an external supply or charging voltage.
13. Now switch on the external supply or charging voltage.
Note:
If you are using a power supply unit without an integrated energy store, the external supply or
charging voltage must be switched on before the optional step during which the connection to the server
is tested.
52
Rev. 05