Chapter 8 Initial Start-Up
7. Remove the antenna again.
The following work is completed directly at the location of the device:
8. Complete all of the steps detailed in the chapter "Assembling the myDatalogEASY V3 " on page 47.
9. Check whether the connection to the myDatanet server has worked correctly (see "Testing
communication with the device" on page 79).
8.5 Testing communication with the device
1. Create a site for operation on the myDatanet server (see "Creating the site" on page 107).
Note:
A "rapidM2M " type site or a site based on an IoT application that is compatible with the
"rapidM2M " site type must be created to operate the myDatalogEASY V3 .
2. Configure the created site/application according to your requirements (see "Site configuration" on page
82). If the site was not created based on an IoT application, you must determine the Data Descriptor
and Device Logic via the "Control" configuration section (see "Control" on page 83).
3. Connect the antenna (see "Connecting the GSM antenna" on page 64). The antenna is not included in
the scope of delivery and must be ordered separately.
4. Establish a connection. If no script has been loaded in the device yet, this can be achieved by inserting
the power supply unit as described in the chapter "Assembling the myDatalogEASY V3 " on page 47. If
a Device Logic has already been loaded in the device, execute the operations provided in the Device
Logic to trigger the establishment of a connection.
Note:
Note that all power supply units with an integrated and rechargeable energy store are delivered
with a maximum charge of 30% in accordance with applicable transport regulations and must therefore
be fully charged before being used for the first time (see "Charging the power supply unit" on page 249).
Note:
If you are using a power supply unit without an integrated energy store, the external supply or
charging voltage must be connected before inserting the power supply unit. Details on this are provided
in the chapter "Connecting the sensors, actuators and power supply" on page 60.
Inserting the power supply unit
1
Power supply unit
2
Base unit
Rev. 05
79
Summary of Contents for myDatalogEASY V3
Page 2: ......
Page 13: ...Chapter 2 Declaration of conformity Chapter 2 Declaration of conformity Rev 05 13 ...
Page 14: ......
Page 42: ......
Page 76: ......
Page 88: ......
Page 102: ......
Page 110: ......
Page 116: ......
Page 234: ......
Page 244: ......
Page 252: ......
Page 254: ......
Page 266: ......
Page 276: ......