Chapter 8 Initial Start-Up
8. Check the incoming data in the ALOHA data window of the myDatanet server, which can be
accessed by clicking on the speech bubble with the "Aloha" inscription (see "myDatanet
Server Manual " 805002). Particular attention must be paid to the internal"GSM level" and
"Battery" measurement values.
Note: Additional explanation about evaluating the "GSM level":
"GSM level"
>-64dBm
-64 to -73dBm
-74 to -83dBm
-84 to -93dBm
-94 to -107dBm
<= -108dBm
Note: Additional explanation about evaluating the "Battery":
"Battery"
> 3,82V
3,82V...3,73V
3,72V...3,66V
3,65V...3,62V
3,61V...3,21V
<= 3,2V or invalid value
Rev. 06