Note:
Additional explanation on "Digital" mode
Invert
Setpoint
Output on the device
Off
Off
=
Off (low)
Off
On
=
On (high)
On
Off
=
On (high)
On
On
=
Off (low)
Note:
Example to explain the burst interval in conjunction with the ext. warmup time (ext. warmup time < measurement
cycle):
Basic setting
Record interval
5min.
Burst interval
60 sec.
Measurement cycle
15 sec.
Output channels
Ext warmup time
5 sec.
Measurement channels -
>Config.
Decay
med
Time
60 sec.
Output on the device
Sensor supply
Formation of the measurement value: In each case, the sensor supply is activated 5 sec before expiry of the
measurement cycle. This results in four valid measurements that are used to determine a median and are recorded
as the measurement value.