5.1.8 Record module
The record module records the measurement values. As the record interval and measurement cycle
can be selected individually, a record is not completed at the time of every measurement.
Depending on the global triggers set by the alarm/trigger module (see "Alarm flags" on page 33 or
"Trigger flags" on page 33), the record interval is modified, the transmission is initiated or a new
measurement is triggered, if necessary.
The following tables specify the relevant parameters for the module:
Configuration section
Mode
Parameter
Explanation
Measurement channels ->
Trigger
Digital
LP digital
QU
Fastrecording (record interval = record
interval / factor)
SL
Slow recording (record interval = record
interval * factor)
MS
Start measurement cycle immediately
XM
Initiate transmission
ON
Activate online mode
Cnt.Day
Cnt.Intervl.
Freq
PWM
0-20 mA
4-20 mA
0-2 V
0-10 V
QU
Fastrecording (record interval = record
interval / factor)
SL
Slow recording (record interval = record
interval * factor)
RO
Switch on recording
RF
Switch off recording
XM
Initiate transmission
ON
Activate online mode
Internal channels ->
Trigger
---
QU
Fastrecording (record interval = record
interval / factor)
SL
Slow recording (record interval = record
interval * factor)
RO
Switch on recording
RF
Switch off recording
XM
Initiate transmission
ON
Activate online mode
Configuration section
Parameter
Explanation
Alarm settings
On alarm
On warning
On fault alarm
On fault warning
Ü
An immediate transmission is initiated.
32
Rev. 06
Summary of Contents for myDatalogEASYplus
Page 2: ......
Page 8: ...Chapter 18 Contact information 139 8 Rev 06 ...
Page 9: ...Chapter 2 Declaration of conformity Chapter 2 Declaration of conformity Rev 06 9 ...
Page 10: ......
Page 22: ......
Page 40: ......
Page 62: ......
Page 101: ...Chapter 9 User interfaces 9 2 2 4 GPRS SIM tariff Selected SIM tariff Rev 06 101 ...
Page 102: ......
Page 110: ......
Page 112: ......
Page 118: ......
Page 120: ......
Page 136: ......
Page 138: ......