Chapter 6 Functional principle
The following table specifies the relevant parameter for the module:
Configuration section
Parameter
Explanation
Measurement channels ->
Basic
Sensor offs.
Specifies the installation height of the sensor (see
"Additional explanation on the zero point adjustment
and installation height of the pressure sensor" on page
84)
6.1.4 Taking the trimming into consideration
This step enables you to adjust the zero point without having to change the value for the "Sensor Offset"
again. The "Trimming" configuration parameter is added to the fill level from the previous step corrected by
the "Sensor Offset". This means that a negative prefix must be set for the "Trimming" parameter (see
"Additional explanation on the zero point adjustment and installation height of the pressure sensor" on page
84) if the fill level should be reduced when adjusting the zero point.
The following table specifies the relevant parameter for the module:
Configuration section
Parameter
Explanation
Measurement channels ->
Basic
Trim
Provided to adjust the zero point (see "Additional
explanation on the zero point adjustment and
installation height of the pressure sensor" on page 84)
6.1.5 Alarm/trigger module
This module monitors the alarm limits and trigger levels and creates an entry in the alarm list if necessary. An
immediate transmission is also triggered in the event of a warning or alarm. For the measurement channels
both the alarm and trigger function of the module are available. However, only the alarm function is available
for the internal channels.
All of the parameters of the "Alarms" and "Trigger" tabs of the "Measurement channels" configuration section
(see "Measurement channels" on page 83) and all of the parameters of the "Alarms" tab of the "Internal
channels" configuration section (see "Internal channels" on page 86) are relevant to this module.
6.1.6 Record module
The record module records the measurement values. Depending on the triggers set by the alarm/trigger
module, the record interval is modified, the transmission cycle is changed, the transmission is initiated or an
immediate recording is triggered, if necessary.
The following table specifies the relevant parameters for the module:
Configuration section
Parameter
Explanation
Measurement channels ->
Trigger
RI
Execute recording immediately
XM
Initiate transmission
RA
The alternative record interval should be used.
QX
The alternative transmission cycle should be used.
Rev. 01
39
Summary of Contents for myDatalogGauge 3G
Page 2: ......
Page 10: ...2 2 BLE Gauge 10 Rev 01 ...
Page 11: ...Chapter 2 Declaration of conformity Rev 01 11 ...
Page 12: ......
Page 13: ...Chapter 3 Ex certification Chapter 3 Ex certification 3 1 BLE 3G Gateway ATEX Rev 01 13 ...
Page 14: ...14 Rev 01 ...
Page 15: ...Chapter 3 Ex certification Rev 01 15 ...
Page 16: ...16 Rev 01 ...
Page 17: ...Chapter 3 Ex certification 3 2 BLE Gauge Rev 01 17 ...
Page 18: ...18 Rev 01 ...
Page 19: ...Chapter 3 Ex certification Rev 01 19 ...
Page 20: ...20 Rev 01 ...
Page 134: ......
Page 140: ......
Page 152: ......
Page 154: ......