Chapter 10 User interfaces
10.2.1.1.5.2 Alarms
"Internal channels" configuration section, "Alarms" tab
1
A warning is triggered, if the measurement value drops to or below this value.
2
A warning is triggered, if the measurement value meets or exceeds this value.
3
An alarm is triggered, if the measurement value drops to or below this value.
4
An alarm is triggered, if the measurement value meets or exceeds this value.
5
Hysteresis for all-clear in event of alarm/warning (e.g. hyst = 5%, alarm or warning at 100 -> all-clear at
95)
6
An "alarm" is triggered when the battery of the BLE Gauge is depleted.
Rev. 01
87