Chapter 10 User interfaces
10.2.1.1.7 Calculated channels
Note:
The values of the calculated channels are directly calculated for every data output (display on the
myDatanet server or download from the myDatanet server). They are not saved in the server database.
10.2.1.1.7.1 Basis
"Calculated channels" configuration section, "Basis" tab
1
Freely selectable channel title for the calculated channels [0-16 characters]
2
Possible calculation modes for the calculated channels
Off
Calculated channel deactivated
Table
Determines the value for the calculated channel by searching for the row corresponding
to the value of a measurement channel in the reference point table. Such a row is made
up of the "Measurement channel value" and "Output value for calculated channel" pair of
values. Linear interpolation is carried out between the table rows; linear extrapolation is
used for values outside the defined table.
Digital
Converts an analogue value into a digital value. The threshold from which an analogue
value is interpreted as "high" can be selected via the "High level" parameter in the
"Calculation" tab. In addition the determined digital value can be inverted via the "Invert"
parameter.
+, -, x, /
Links the values of two measurement channels using a mathematic operation (addition,
subtraction, multiplication or division)
Delta
Determines the difference between two measurement values and divides the result by
the time difference between the time stamps of the measurement values. The time unit
(value/sec., value/min., ...) for the result can be selected via the "Time basis" parameter
located in the "Calculation" tab. It is thus possible to convert the counter reading (m
3
) of
the source in to a flow rate (m
3
/min.) (see "Additional explanation: Delta mode" on page
97).
clone
Creates a clone of a measurement channel. This ensures it is possible to rename
channels, to select different ends of the scale for the pointer instruments, to determine a
new string as a measurement unit and to adjust the number of decimal places. The
measurement values (numerical value without unit) correspond exactly to those of the
source.
3
Defines the lower scale end of the pointer instruments
Rev. 01
89
Summary of Contents for myDatalogGauge 3G
Page 2: ......
Page 10: ...2 2 BLE Gauge 10 Rev 01 ...
Page 11: ...Chapter 2 Declaration of conformity Rev 01 11 ...
Page 12: ......
Page 13: ...Chapter 3 Ex certification Chapter 3 Ex certification 3 1 BLE 3G Gateway ATEX Rev 01 13 ...
Page 14: ...14 Rev 01 ...
Page 15: ...Chapter 3 Ex certification Rev 01 15 ...
Page 16: ...16 Rev 01 ...
Page 17: ...Chapter 3 Ex certification 3 2 BLE Gauge Rev 01 17 ...
Page 18: ...18 Rev 01 ...
Page 19: ...Chapter 3 Ex certification Rev 01 19 ...
Page 20: ...20 Rev 01 ...
Page 134: ......
Page 140: ......
Page 152: ......
Page 154: ......