Chapter 14 Troubleshooting and repair
Log entry
Parameter
Description
Code
Plain text
Code
Plain text
TCP channel error (2/2)
1200 CHANNEL REFUSED -955 ---
The TCP connection has been refused by the
server.
Try again later
CHANNEL HOST
UNREACHABLE
-954 ---
No route to the host.
Try again later
CHANNEL NETWORK
UNREACHABLE
-953 ---
No network available
Try again later
CHANNEL PIPE
BROKEN
-952 ---
TCP connection interrupted
Try again later
CHANNEL TIMEOUT -951 ---
Timeout (DNS request, TCP connection, ping
response, etc.)
Try again later
CHANNEL
UNKNOWN
-950 ---
Internal error
14.3 Evaluating the device log
14.3.1 Evaluating the device log on the myDatanet server
The last 300 log entries on the myDatanet server can be called up via the button shown below that
is located in the measurement device list. As the log entries are sent to the server in the
transmission cycle in the same way as the measurement data, only the log entries up to the last
server connection are available.
The manual for the server ("myDatanet Server Manual " 805002) includes a detailed description of
the evaluation of the device log on the myDatanetserver.
14.3.2 Evaluating the device log using DeviceConfig
Important note: Use of the "Cable set NANO USB " (300251 ) is NOT permissible in the Ex
area.
The optional equipment "Cable set NANO USB " (300251 ) is required to read the log entries directly
from the myDatalogNANO Ex using the program DeviceConfig . With this equipment all of the log
Rev. 01
101
Summary of Contents for myDatalogNANO Ex
Page 2: ......
Page 8: ......
Page 9: ...Chapter 2 Declaration of conformity Chapter 2 Declaration of conformity Rev 01 9 ...
Page 10: ...2 1 Declaration of conformity Appendix 10 Rev 01 ...
Page 11: ...Chapter 2 Declaration of conformity Rev 01 11 ...
Page 12: ......
Page 24: ......
Page 52: ......
Page 78: ......
Page 86: ......
Page 92: ......
Page 104: ......
Page 108: ......
Page 110: ......