1. Connect the Pressure compensation tube with 1x 0/4-20mA 24VDC (300255 ) with the
myDatalogNANO .
2. On the pressure compensation clamping tube loosen the connecting nut of the cable screw connection
facing the myDatalogNANO .
Loosening the connecting nut
3. Now remove the other cable screw connection of the pressure compensation clamping tube.
Removing the cable screw connection
4. Push the pressure compensation clamping tube over the cable until the terminal strip of the 0/4-20mA
board can be seen.
Important note:
Prior to this, clean the cable in the area where the pressure compensation
clamping tube will be pushed over the cable, so that no impurities can penetrate between the
cable and seal of the cable screw connection.
Exposing the 0/4-20mA board
5. Now connect your sensor with the 0/4-20mA board.
Important note:
The sensor cable must also be cleaned to guarantee the tightness of the
cable screw connection.
Connecting the sensor
6. Carefully push the 0/4-20mA board into the pressure compensation clamping tube and tighten the
connecting nut of the cable screw connection facing the myDatalogNANO .
48
Rev. 02