Chapter 9 User interfaces
9.2.1.4.1 Basis
Title 1-5
Freely selectable channel title for the calculated channels [0-16 characters]
Mode
Possible calculation modes for the calculated channels
Off
---
Calculated channel deactivated
Table
Min
Defines the lower scale end of the pointer instruments
Max
Defines the upper scale end of the pointer instruments
Unit
String that is used as a measurement unit by all of the server display
elements [0-16 characters]. It has no direct influence on the values
Decimal
places
Number of decimal places that are used by all of the server display elements
Digital
Invert
Inverts the input signal
+, -, x, /
Min
Defines the lower scale end of the pointer instruments
Max
Defines the upper scale end of the pointer instruments
Unit
String that is used as a measurement unit by all of the server display
elements [0-16 characters]. It has no direct influence on the values
Decimal
places
Number of decimal places that are used by all of the server display elements
Delta
Determines the difference between two measurement values and divides the result by the
time difference between the time stamps of the measurement values. The time unit
(value/sec., value/min., ...) for the result can be selected via the "Time basis" parameter
located in the "Calculation" tab. It is thus possible to convert the counter reading (m
3
) of the
source in to a flow rate (m
3
/min.) (see "Additional explanation: Delta mode" on page 83).
Min
Defines the lower scale end of the pointer instruments
Max
Defines the upper scale end of the pointer instruments
Unit
String that is used as a measurement unit by all of the server display
elements [0-16 characters]. It has no direct influence on the values
Decimal
places
Number of decimal places that are used by all of the server display elements
clone
Creates a clone of a measurement channel. This ensures it is possible to rename channels,
to select different ends of the scale for the pointer instruments, to determine a new string as
a measurement unit and to adjust the number of decimal places. The measurement values
(numerical value without unit) correspond exactly to those of the source.
Min
Defines the lower scale end of the pointer instruments
Max
Defines the upper scale end of the pointer instruments
Unit
String that is used as a measurement unit by all of the server display
elements [0-16 characters]. It has no direct influence on the values
Decimal
places
Number of decimal places that are used by all of the server display elements
Rev. 02
81
Summary of Contents for myDatalogNANO
Page 2: ......
Page 8: ......
Page 9: ...Chapter 2 Declaration of conformity Chapter 2 Declaration of conformity Rev 02 9 ...
Page 10: ......
Page 12: ......
Page 22: ......
Page 34: ......
Page 38: ......
Page 58: ......
Page 92: ......
Page 108: ......
Page 118: ......
Page 120: ......
Page 126: ......
Page 130: ......